Constant Dose Rate Vmat in Raystation

ثبت نشده
چکیده

When optimizing variable dose rate VMAT (VDR) beams, the leaf positions and the MU of each control point are optimized simultaneously (Figure 1). Since the MU is not allowed to be individually optimized for each control point for a constant dose rate VMAT (CDR) beam (Figure 2), it is likely that the plan quality is reduced compared to a VDR beam with the same angle settings. To obtain a good quality dose distribution using CDR, the delivery time is usually increased compared to the VDR beam. The reason is that the gantry is not allowed to move faster from the directions where little dose is desired. Instead the optimizer closes the leaves faster from these directions to create smaller MLC openings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of constant dose rate VMAT in the treatment of nasopharyngeal cancer patients

PURPOSE To investigate the feasibility of constant dose rate volumetric modulated arc therapy (CDR-VMAT) in the treatment of nasopharyngeal cancer (NPC) patients and to introduce rotational arc radiotherapy for linacs incapable of dose rate variation. MATERIALS AND METHODS Twelve NPC patients with various stages treated previously using variable dose rate (VDR) VMAT were enrolled in this stud...

متن کامل

Point dose measurements in VMAT: an investigation of detector choice and plan complexity

Purpose: Volumetric Modulated Arc Therapy (VMAT) is an intensity modulated radiation therapy technique which can achieve highly conformal dose delivery through dynamic variation of dose rate, gantry speed, and multileaf collimator positions. Due to the complexity of treatment delivery, patient specific quality assurance (QA) is required to ensure agreement between calculated and delivered dose....

متن کامل

Volumetric‐modulated arc therapy using multicriteria optimization for body and extremity sarcoma

This study evaluates the implementation of volumetric-modulated arc therapy (VMAT) using multicriteria optimization (MCO) in the RayStation treatment planning system (TPS) for complex sites, namely extremity and body sarcoma. The VMAT-MCO algorithm implemented in RayStation is newly developed and requires an integrated, comprehensive analysis of plan generation, delivery, and treatment efficien...

متن کامل

Clinical implementation of a knowledge based planning tool for prostate VMAT

BACKGROUND A knowledge based planning tool has been developed and implemented for prostate VMAT radiotherapy plans providing a target average rectum dose value based on previously achievable values for similar rectum/PTV overlap. The purpose of this planning tool is to highlight sub-optimal clinical plans and to improve plan quality and consistency. METHODS A historical cohort of 97 VMAT pros...

متن کامل

Quantification and modelling of the dosimetric impact of the treatment couch in volumetric modulated arc therapy (VMAT)

Background: As the volumetric modulated arc therapy (VMAT) becoming a main role of treatment ways, the effect of couch top becomes more significant. It is imperative to re-evaluate the couches that previously may have been considered of no importance during early treatment techniques. The impact of couch top on radiation delivery was explored and the couch model was tested with the aim of reduc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017