Asymmetric collimation can significantly reduce patient radiation dose during pulmonary vein isolation.
نویسندگان
چکیده
AIMS Current fluoroscopic and 3D image-guided treatment of atrial fibrillation (AF) by radiofrequency ablation is characterized by a substantial amount of X-ray radiation. We investigated the potential of an asymmetric collimation technique to reduce dose. METHODS AND RESULTS For 30 patients, referred for AF ablation, we determined the received fluoroscopy dose for various collimation scenarios: a single collimation window encompassing all veins as used in most labs (Sc 1), an optimal adjusted symmetric collimation window encompassing each two ipsilateral veins (Sc 2) or each individual vein (Sc 3) and an optimal asymmetric collimation window encompassing each two ipsilateral veins (Sc 4) or each individual vein (Sc 5). Twenty patients were studied retrospectively and 10 were studied prospectively. Total fluoroscopy effective dose for all collimation strategies amounted to 45 ± 31 mSv for a single collimation field (Sc 1), 36 ± 25 mSv (Sc 2), and 24 ± 14 mSv (Sc 3) for a symmetrically adjusted collimation window and 15 ± 10 (Sc 4) and 5 ± 3 mSv (Sc 5) for an asymmetrically adjusted collimation approach. Validation of symmetric (Sc 2) and asymmetric (Sc 4) collimation in 10 patients confirmed the retrospective analysis. CONCLUSIONS Implementation and effective application of an optimal asymmetric collimation approach would yield an average three- to nine-fold reduction of fluoroscopy dose during AF ablation procedures. This reduction exceeds what has been previously reported by implementing an electromagnetic catheter tracking approach. Furthermore, it can be easily integrated in the clinical workflow with limited additional one-time cost. Manufacturers of imaging systems should consider its implementation a priority, and physicians should adopt it in their workflow.
منابع مشابه
Observations and Considerations on Patient X-ray Exposure in the Electrophysiology Lab.
To assess patient radiation during catheter ablation procedures and operator differences. From 84 patients (51 males, age 63 ± 10 years) undergoing complex catheter ablation by three experienced operators we collected: body mass index (BMI), procedure type and time, fluoroscopy time, dose area product (DAP), air kerma and X-ray system setting (cine, collimation and angiographic imaging angle). ...
متن کاملBeam Collimation during Lumbar Spine Radiography: A Retrospective Study
Introduction: Collimating the primary beam to the area of diagnostic interest (ADI) has been strongly recommended as an effective method to reduce patient’s radiation dose and to improve image quality during radiology practice. Lack or inadequate collimation results in excessive radiation dose to patients and deterioration image quality.Objective: To assess the quality of beam collimation dur...
متن کاملEstimation of radiation dose of emergency exposure during the hospitalized 131I therapy patient
Background: The aim of the study was to estimate the radiation dose during emergency exposure to patients treated with iodine-131 during the isolation period. Materials and Methods: The dose rate from a sample of 192 patients administrated by three different radioactivity of 131I (3.7, 5.55 and 7.4 GBq) was measured, at 1 meter after 1, 24 and 48 hours post dose administration, at three d...
متن کاملTotally endoscopic microwave ablation for lone atrial fibrillation: an alternative method of treatment.
Recent studies suggest that pulmonary vein isolation can be an effective method of treatment for atrial fibrillation. This procedure can be performed with minimally invasive, totally endoscopic cardiac surgical techniques. We report our first successful endoscopic isolation of the pulmonary veins in a patient with paroxysmal atrial fibrillation. The procedure consisted of making a box lesion ar...
متن کاملDose Reduction Methods in Chest Computed Tomography
Introduction: Computed tomography is one of the most powerful tools for investigating thorax disease, because it shows progression of lung disease much clearer than chest radiography. Technical advances in CT scanners have led to some abilities for CT scanners such as coverage of larger volume, lower noise and ability for acquiring image in one respiratory phase. However, this will be accompani...