Detection of a spontaneous pulse in photoplethysmograms during automated cardiopulmonary resuscitation in a porcine model.

نویسندگان

  • Ralph W C G R Wijshoff
  • Toeno van der Sar
  • Wouter H Peeters
  • Rick Bezemer
  • Paul Aelen
  • Igor W F Paulussen
  • Simone C M A Ordelman
  • Alyssa Venema
  • Paul F J van Berkom
  • Ronald M Aarts
  • Pierre H Woerlee
  • Gert-Jan Scheffer
  • Gerrit J Noordergraaf
چکیده

INTRODUCTION Reliable, non-invasive detection of return of spontaneous circulation (ROSC) with minimal interruptions to chest compressions would be valuable for high-quality cardiopulmonary resuscitation (CPR). We investigated the potential of photoplethysmography (PPG) to detect the presence of a spontaneous pulse during automated CPR in an animal study. METHODS Twelve anesthetized pigs were instrumented to monitor circulatory and respiratory parameters. Here we present the simultaneously recorded PPG and arterial blood pressure (ABP) signals. Ventricular fibrillation was induced, followed by 20 min of automated CPR and subsequent defibrillation. After defibrillation, pediatric-guidelines-style life support was given in cycles of 2 min. PPG and ABP waveforms were recorded during all stages of the protocol. Raw PPG waveforms were acquired with a custom-built photoplethysmograph controlling a commercial reflectance pulse oximetry probe attached to the nose. ABP was measured in the aorta. RESULTS In nine animals ROSC was achieved. Throughout the protocol, PPG and ABP frequency content showed strong resemblance. We demonstrate that (1) the PPG waveform allows for the detection of a spontaneous pulse during ventilation pauses, and that (2) frequency analysis of the PPG waveform allows for the detection of a spontaneous pulse and the determination of the pulse rate, even during ongoing chest compressions, if the pulse and compression rates are sufficiently distinct. CONCLUSIONS These results demonstrate the potential of PPG as a non-invasive means to detect pulse presence or absence, as well as pulse rate during CPR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of spontaneous pulse using the acceleration signals acquired from CPR feedback sensor in a porcine model of cardiac arrest

BACKGROUND Reliable detection of return of spontaneous circulation with minimal interruptions of chest compressions is part of high-quality cardiopulmonary resuscitation (CPR) and routinely done by checking pulsation of carotid arteries. However, manual palpation was time-consuming and unreliable even if performed by expert clinicians. Therefore, automated accurate pulse detection with minimal ...

متن کامل

PetCO2, VCO2 and CorPP Values in the Successful Prediction of the Return of Spontaneous Circulation: An Experimental Study on Unassisted Induced Cardiopulmonary Arrest

Introduction: During cardiac arrest, end-tidal CO2 (PetCO2), VCO2 and coronary perfusion pressure fall abruptly and tend to return to normal levels after an effective return of spontaneous circulation. Therefore, the monitoring of PetCO2 and VCO2 by capnography is a useful tool during clinical management of cardiac arrest patients. Objective: To assess if PetCO2, VCO2 and coronary perfusion pre...

متن کامل

Success rate of cardiopulmonary resuscitation in the intensive care unit of an Iran’s Army Air Force hospital in 2012

  Purpose: Cardiopulmonary resuscitation (CPR) is an important step for patient survival inside   and outside the hospital. Therefore, the results of CPR can be effective in modifying the structure   of this operation and in eliminating its shortcomings. The purpose of this study was to evaluate   the success rate of CPR in intensive care unit of an Iran’s Army Air Force hospital in 2012.   Mat...

متن کامل

A feasibility study of cerebral oximetry during in-hospital mechanical and manual cardiopulmonary resuscitation*.

OBJECTIVE A major hurdle limiting the ability to improve the quality of resuscitation has been the lack of a noninvasive real-time detection system capable of monitoring the quality of cerebral and other organ perfusion, as well as oxygen delivery during cardiopulmonary resuscitation. Here, we report on a novel system of cerebral perfusion targeted resuscitation. DESIGN An observational study...

متن کامل

Cardiopulmonary resuscitation (CPR) using periodic acceleration (pGz) in an older porcine model of ventricular fibrillation.

Cardiopulmonary resuscitation (CPR) can be achieved by repetitive motion of the body headwards to footwards in the spinal axis, at 2 Hz and +/- 0.6 G in a juvenile pig model of ventricular fibrillation. Return of spontaneous circulation and normal neurological outcome occurred after a total of 22 min of ventricular fibrillation that included a 3-min noninterventional period [Resuscitation 56 (2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Resuscitation

دوره 84 11  شماره 

صفحات  -

تاریخ انتشار 2013