Detection of internal carotid artery stenosis with duplex velocity criteria using receiver operating characteristic analysis.

نویسندگان

  • Hoe-Chin Chua
  • Yih-Yian Sitoh
  • Arul Earnest
  • N Venketasubramanian
چکیده

INTRODUCTION Duplex ultrasonography is an excellent non-invasive screening tool for carotid artery stenosis. The aim of this study was to evaluate optimal ultrasonographic criteria for determination of internal carotid artery stenosis with reference to digital subtraction angiography. MATERIALS AND METHODS From January 1995 to December 2003, 114 symptomatic patients underwent both duplex ultrasonography and angiography. Seven velocity criteria were compared with angiographic stenosis and receiver operating characteristic curves were used to determine the best cutoff for each criteria. RESULTS Internal carotid artery/common carotid artery systolic velocity ratios (PSV ICA/PSV CCA) and systolic internal carotid artery/diastolic common carotid artery ratios (PSV ICA/EDV CCA) were superior to other criteria for diagnosing internal carotid artery stenosis. For 50% stenosis, the best criterion of PSV ICA/PSV CCA was 1.5 [sensitivity 100%, specificity 85%, area under the curve (AUC) 99%], and the best criterion of PSV ICA/EDV CCA was 3.5 (sensitivity 100%, specificity 58%, AUC 99%). For 60% stenosis, the best criterion of PSV ICA/PSV CCA was 2.6 (sensitivity 100%, specificity 94%, AUC 99%), and the best criterion of PSV ICA/EDV CCA was 10.3 (sensitivity 100%, specificity 96%, AUC 99%). For 70% stenosis, the best criterion of PSV ICA/PSV CCA was 3.1 (sensitivity 100%, specificity 91%, AUC 99%), and the best criterion of PSV ICA/EDV CCA was 10.3 (sensitivity 100%, specificity 91%, AUC 99%). CONCLUSION Our study showed that velocity ratios are superior to other criteria for detecting carotid stenosis. Each laboratory needs to validate its own results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic performance of duplex ultrasonography in the detection of high grade internal carotid artery stenosis.

OBJECTIVES to establish on a national basis whether the diagnostic accuracy of carotid duplex justifies carotid surgery without preoperative angiography. DESIGN prospective national multicentre study with 10 participating university and county hospitals. MATERIAL AND METHODS one hundred and thirty-four patients, aged 69+/-9 years, were subjected to routine carotid duplex ultrasonography and...

متن کامل

Carotid duplex ultrasound velocity measurements versus intravascular ultrasound in detecting carotid in-stent restenosis.

BACKGROUND Duplex ultrasonography criteria for assessing the severity of carotid artery (CA) in-stent restenosis are not well established. METHODS AND RESULTS We analyzed 39 patients (40 CAs) who underwent CA stenting with baseline and 6-month follow-up carotid duplex ultrasonography and intravascular ultrasound. Intravascular ultrasound measurements included minimum luminal diameter, percent...

متن کامل

Standardization of carotid ultrasound: a hemodynamic method to normalize for interindividual and interequipment variability.

BACKGROUND AND PURPOSE Accurate carotid Doppler examination is an important issue in the light of large endarterectomy trials, but recommended cutoff values for detection of >70% stenosis vary widely. Standardization of diagnostic criteria should consider patient variation and instrument variability. METHODS We prospectively analyzed various Doppler parameters in 44 patients undergoing caroti...

متن کامل

Changes over time in optimal duplex threshold for the identification of patients eligible for carotid endarterectomy.

BACKGROUND AND PURPOSE Two surgical trials established that carotid endarterectomy is beneficial to symptomatic patients who have a severe internal carotid artery (ICA) stenosis on angiograms. Duplex ultrasonography-derived hemodynamic parameters show a good correlation with angiography and are often used for detecting severe ICA stenoses. However, duplex performance is ultrasound machine and o...

متن کامل

Prediction of the exact degree of internal carotid artery stenosis using an artificial neural network based on duplex velocity measurements.

Duplex ultrasound criteria use a combination of velocity measurements to evaluate internal carotid artery (ICA) stenosis. These evaluations divide ICA stenosis into broad categories. The aim of this study was to design an artificial neural network (ANN) capable of predicting the exact degree of ICA stenosis based on duplex velocity measurements. Consecutive patients with significant carotid ath...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of the Academy of Medicine, Singapore

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 2007