A molecularly imprinted polymer as the sorptive phase immobilized in a rotating disk extraction device for the determination of diclofenac and mefenamic acid in wastewater.
نویسندگان
چکیده
The microextraction of diclofenac and mefenamic acid from water samples was performed by using rotating disk sorptive extraction (RDSE) with molecularly imprinted polymer (MIP) as the sorptive phase. The MIP was synthesized from the monomer 1-vinylimidazol (VI) together with the cross-linker divinylbenzene (DVB) using diphenylamine as the template molecule. Scanning electron microscopy (SEM) analyses of the MIP revealed clusters of spherical particles having a narrow size distribution, with diameters of approximately 1 μm. The optimized extraction conditions involved a disk rotation velocity of 3000 rpm, an extraction time of 120 min, a sample volume of 50 mL, and a sample pH of 2 as well as 25 mg of MIP immobilized in the disk. Desorption of the extracted analytes was performed with 5 mL of methanol for 10 min. Analysis by gas chromatography-mass spectrometry (GC-MS) was carried out after derivatization of the analytes with N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide (MTBSTFA). Nonmolecularly imprinted polymer (NIP) was also synthesized for comparison. It was observed that under the same conditions, MIP extracted significantly more NSAIDs containing diphenylamine (or part of this molecule) in their structure than NIP. Higher significant differences between MIP and NIP were observed for diclofenac, mefenamic acid and paracetamol, clearly indicating the effect of the template on the extraction. Recoveries of the method were between 100 and 112%, with relative standard deviations of 5-6%. The limits of detection were between 60 and 223 ng L(-1). Water samples from a wastewater treatment plant (WWTP) of Santiago de Chile, were found to contain concentrations of these acidic drugs between 1.6 and 4.3 μg L(-1) and between 1.4 and 3.3 μg L(-1) in the influent and effluent, respectively.
منابع مشابه
Molecularly Imprinted Stir Bar Sorptive Extraction Coupled with High-Performance Liquid Chromatography for Trace Analysis of Diclofenac in Different Real Samples
A novel molecularly imprinted polymer-coated stir bar has been used to selectively extract diclofenac (DFC) directly from real samples. DFC was used as template molecule for preparation of MIP coating. The effect of different parameters on the extraction efficiency were studied and the optimum conditions were established as: the absorption and desorption times were fixed at 10 min, stirring...
متن کاملSelective Extraction and Determination of Di(2-ethylhexyl) Phthalate in Aqueous Solution by HPLC Coupled with Molecularly Imprinted Solid-phase Extraction
Surface Molecularly Imprinted Polymer (SMIP) for selective adsorption of di(2-ethylhexyl) phthalate(DEHP) was prepared on the surface of silica gel which was modified by aminopropyltriethoxysilane and acryloyl chloride in a two-step method. The prepared SMIP was used to prepare Molecularly Imprinted Solid-Phase Extraction (MISPE) column for selective extraction of DEHP from aqueous solution...
متن کاملComputational Aided-Molecular Imprinted Polymer Design for Solid Phase Extraction of Metaproterenol from Plasma and Determination by Voltammetry Using Modified Carbon Nanotube Electrode
A molecular imprinted polymer (MIP) was computationally designed and synthesized for the selective extraction of metaproterenol (MTP), from human plasma. In this regards semi empirical MP3 and mechanical quantum (DFT) calculations were used to find a suitable functional monomers. On the basis of computational and experimental results, acrylic acid (AA) and DMSO:MeOH (90:10 %V/V) were found to b...
متن کاملComputational Aided-Molecular Imprinted Polymer Design for Solid Phase Extraction of Metaproterenol from Plasma and Determination by Voltammetry Using Modified Carbon Nanotube Electrode
A molecular imprinted polymer (MIP) was computationally designed and synthesized for the selective extraction of metaproterenol (MTP), from human plasma. In this regards semi empirical MP3 and mechanical quantum (DFT) calculations were used to find a suitable functional monomers. On the basis of computational and experimental results, acrylic acid (AA) and DMSO:MeOH (90:10 %V/V) were found to b...
متن کاملPreconcentration and Determination of Mefenamic Acid in Pharmaceutical and Biological Fluid Samples by Polymer-grafted Silica Gel Solid-phase Extraction Following High Performance Liquid Chromatography
Abstract Mefenamic acid is a nonsteroidal anti-inflammatory drug (NSAID) that has analgesic,anti-infammatory and antipyretic actions. It is used to relieve mild to moderate pains. Solid-phase extraction of mefenamic acid by a polymer grafted to silica gel is reported . Poly allyl glycidyl ether/iminodiacetic acid-co-N, N-dimethylacrylamide was synthesized and grafted to silica gel and was used ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytica chimica acta
دوره 889 شماره
صفحات -
تاریخ انتشار 2015