Evaluation of a short formation on the performance of point-of-care renal ultrasound performed by physicians without previous ultrasound skills: prospective observational study

نویسندگان

  • François Javaudin
  • François Mounier
  • Philippe Pes
  • Idriss Arnaudet
  • Frédéric Vignaud
  • Eric Frampas
  • Philippe Le Conte
چکیده

BACKGROUND Point-of-Care Ultrasound (PoCUS) is recommended by emergency medicine societies for the detection of hydronephrosis. Training of certified Emergency Physicians (EP) without prior ultrasound experience remains debated. We investigate performance of a brief training session for the detection of hydronephrosis with PoCUS performed by EP without previous ultrasound experience. PATIENTS AND METHODS This was a prospective observational study of a convenience sample of patients older than 18 years with presumed renal colic, acute pyelonephritis or documented acute renal failure. Exclusion criteria were pregnancy and documented end of life.After inclusion and informed consent, a PoCUS was performed. A radiologist's renal ultrasound (RRUS) was then conducted, the radiologist being blind to PoCUS result.The objective was to determine the diagnostic performance of PoCUS performed by EP for the detection of hydronephrosis using RRUS as gold standard. RESULTS Six EP participated in this study. 55 patients were included, five secondary excluded for lack of RRUS. Age was 47 ± 22 years, sex ratio 1. Hydronephrosis prevalence was 38% (CI 95% [26-52%]). Sensitivity of PoCUS was 100% (CI 95% [82-100%]) while its specificity was 71% (CI 95% [52-86%]) with a NPV of 100% (CI 95% [85-100%]) and a 68% (CI 95% [48-84%]) PPV. Kappa coefficient was 0.65 (CI 95% [0.45-0.85]). DISCUSSION We demonstrated that a short training program enables EP without previous ultrasound skills to rule out hydronephrosis with satisfactory performances. The main limitation was the absence of collection of the number of PoCUS by EP. After this didactic course, an experiential phase must be carried out.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a point of care ultrasound curriculum for Indonesian physicians taught by first-year medical students.

BACKGROUND The purpose of this study was to assess the short-term efficacy of a 4-week ultrasound curriculum taught by American first-year medical students to general practitioners working in public health care clinics, or puskesmas, in Bandung, Indonesia. METHODS We performed a prospective, observational study of Indonesian health care practitioners from public clinics in Bandung, Indonesia....

متن کامل

Short Term Outcome of Antenatal Hydronephrosis: A Single Center Experience

Background Fetal hydronephrosis is a common urinary tract anomaly that may result in renal parenchyma damage. Ultrasound is considered a simple, noninvasive procedure to diagnose and track antenatal hydronephrosis. Our aim was to study the clinical course of fetal hydronephrosis in fetuses. Materials and Methods</...

متن کامل

O-37: Yolk Sac Diameter and Embryonic Heart Rate As Prognostic Factors of First Trimester Spontaneous Miscarriage

Background: During the past 20 years a lot of information is achieved about the first trimester of pregnancy through ultrasound and intrauterine fertilization. Many researchers tried to use the symptoms of ultrasound in early pregnancy like measuring the gestational sac and yolk sac of the pregnancy to predict the continuation of pregnancy. Aim of the recent study is to predict the risk of spon...

متن کامل

Difference between efficiency of ultrasound treatments above and below the membrane surface in membrane clarification of pomegranate juice

Microfiltration can clarify pomegranate juice; however, fouling is a limiting phenomenon in the process. In current work ultrasound was applied above and below the membrane surface to reduce fouling after removing temperature effect. A hydrophilic mixed cellulose ester membrane with pore size of 0.45 μm was used in lab scale flat sheet module. Membrane module was placed above and below the ultr...

متن کامل

Difference between efficiency of ultrasound treatments above and below the membrane surface in membrane clarification of pomegranate juice

Microfiltration can clarify pomegranate juice; however, fouling is a limiting phenomenon in the process. In current work ultrasound was applied above and below the membrane surface to reduce fouling after removing temperature effect. A hydrophilic mixed cellulose ester membrane with pore size of 0.45 μm was used in lab scale flat sheet module. Membrane module was placed above and below the ultr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017