Clinical Significance of Venous Graft Size and Run-Off Segment for Peripheral Bypass Patency

نویسندگان

  • Mihail Cheshmedzhiev
  • Emil Jordanov
  • Miroslav Yordanov
  • Nina Kovacheva
چکیده

Aim: To analyze the one-year-patency of infrainguinal arterial reconstructions in relation to venous graft diameter and length and the run-off segment, when arteries above the proximal anastomosis of the reconstruction are not diseased. Material and Methods: We compared retrospectively for two-year period the diameter, the length of the used vein and the run-off segment in 107 consecutively constructed infrainguinal autovenous bypasses – 54 patent (not less than 1 year) and 53 failed bypasses Diameter of the vein was measured at the narrowest part of the vein (in all cases this was the area of the distal anastomosis). Аll bypassеs are made with translocated nonreversed vein and the length of the vein was measured after the completion of reconstruction. Volume and pressure of blood flow were measured below the distal anastomosis by the means of ultrasound transit-time flowmetry. For the assessment of run-off segment Fourier analyses of flow and pressure were used and alteration of the amplitudes after intragraft infusion of Prostaglandines was calculated. Results: We compared the alteration in amplitudes in failed and patent for at least 1 year bypasses and estimated that ratio below 2 before and after medicamentous vasodilatation, sets the reconstruction in the group of threatened, as well as graft diameter below 3.5 mm and length over 40 cm. Conclusion: Hemodynamic assessment of blood flow below distal anastomosis defines the necessary vein lenght, that is why run-off segment has the most important significance for the patency of the infrainguinal autovenous reconstructions. Shorter grafts with diameter over 3.5 mm do not guarantee longer patency if distal anastomosis is constructed above diseased run-off segment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Significance of Venous Graft Diameter and Length for Peripheral By-pass Patency

http://www.journal-imab-bg.org / J of IMAB. 2013, vol. 19, issue 1 / ABSTRACT: Objective: To analyze the one-year-patency of infrainguinal arterial reconstructions in relation to venous graft diameter and length . Material and Methods: 56 patent and failed infrainguinal autovenous by-pass reconstructions were followed up for no less than a year. The diameter of the vein was measured at the site...

متن کامل

Surgical infrainguinal revascularization for peripheral arterial disease: factors affecting patency rate

Background: Peripheral arterial disease is a source of morbidity and mortality. Surgical vascular reconstruction is a treatment option but probability of failure and complications are important concerns. In this study, we evaluated outcome of surgical infrainguinal reconstruction and factors affecting graft patency for a period of one year. Methods: In this cohort study, 85 consecutive patie...

متن کامل

Long-term patency of sequential and individual saphenous vein coronary bypass grafts.

OBJECTIVES The long-term patency rates for individual and sequential saphenous vein grafts (SVG) as coronary bypass conduits are angiographically compared; the impact of native coronary vessel characteristics is investigated. METHODS A total of 875 distal coronary anastomoses on 500 SVGs were assessed in 430 patients at an average of 5.8+/-3 years after a coronary revascularization procedure....

متن کامل

Management of Catheter Induced Upper Limb Suppurative Thrombophlebitis in a Patient after Coronary Artery Bypass Graft Surgery: a Case Report

Introduction: One of the important complications of peripheral venous catheters is suppurative thrombophlebitis that would be life threatening without treatment. In this report, we introduce a patient who developed purulent thrombophlebitis due to venous catheter in the upper limb after coronary artery bypass graft surgery. Multiple abscess formation was developed on her upper limb after the th...

متن کامل

ارزیابی و مقایسه عوارض وتمامیت فیستول شریانی- وریدی باگرافت گورتکس 6 و 8 میلی‌متری در اندام فوقانی و مقایسه آن‌ها با گرافت گورتکس 8 میلی‌متری اندام تحتانی در یک سال اول پس از عمل

Background & Aims: This study was done in hem dialysis patients who referred to Imam Khomeini hospital of Urmia for insertion of arterial -venous fistula with Gore-tex, in whom there was not possibility of natural fistula. Objectives were assessment and comparison of complications and patency of arterial-venous fistulas was done with 6 and 8 mm Gore-tex graft in the upper limb and comparison of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015