Optical Coherence Tomographic Elastography Reveals Mesoscale Shear Strain Inhomogeneities in the Annulus Fibrosus.

نویسندگان

  • Sang K Han
  • Chao-Wei Chen
  • Kevin M Labus
  • Christian M Puttlitz
  • Yu Chen
  • Adam H Hsieh
چکیده

STUDY DESIGN Basic science study using in vitro tissue testing and imaging to characterize local strains in annulus fibrosus (AF) tissue. OBJECTIVE To characterize mesoscale strain inhomogeneities between lamellar and inter-/translamellar (ITL) matrix compartments during tissue shear loading. SUMMARY OF BACKGROUND DATA The intervertebral disc is characterized by significant heterogeneities in tissue structure and plays a critical role in load distribution and force transmission in the spine. In particular, the AF possesses a lamellar architecture interdigitated by a complex network of extracellular matrix components that form a distinct ITL compartment. Currently, there is not a firm understanding of how the lamellar and ITL matrix coordinately support tissue loading. METHODS AF tissue samples were prepared from frozen porcine lumbar spines and mounted onto custom fixtures of a materials testing system that incorporates optical coherence tomography (OCT) imaging to perform tissue elastography. Tissues were subjected to 20 and 40% nominal shear strain, and OCT images were captured and segmented to identify regions of interest corresponding to lamellar and ITL compartments. Images were analyzed using an optical flow algorithm to quantify local shear strains within each compartment. RESULTS Using histology and OCT, we first verified our ability to visualize and discriminate the ITL matrix from the lamellar matrix in porcine AF tissues. Local AF strains in the ITL compartment (22.0 ± 13.8, 31.1 ± 16.9 at 20% and 40% applied shear, respectively) were significantly higher than corresponding strains in the surrounding lamellar compartment (12.1 ± 5.6, 15.3 ± 5.2) for all tissue samples (P < 0.05). CONCLUSION Results from this study demonstrate that the lamellar and ITL compartments of the AF distribute strain unevenly during tissue loading. Specifically, shear strain is significantly higher in the ITL matrix, suggesting that these regions may be more susceptible to tissue damage and more mechanobiologically active. LEVEL OF EVIDENCE N/A.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MR Elastography-derived Stiffness: A Biomarker for Intervertebral Disc Degeneration.

Purpose To determine the repeatability of magnetic resonance (MR) elastography-derived shear stiffness measurements of the intervertebral disc (IVD) taken throughout the day and their relationship with IVD degeneration and subject age. Materials and Methods In a cross-sectional study, in vivo lumbar MR elastography was performed once in the morning and once in the afternoon in 47 subjects witho...

متن کامل

Constitutive Modeling and Damage Mechanics of the Annulus Fibrosus

by Nathaniel T. Hollingsworth Annulus fibrosus damage has been shown to come from combinations of bending, lifting, and twisting. Although the these motions can induce annulus fibrosus damage, the stress-strain state of the annulus during these motions is not known. The objective of this project was to develop more complete constitutive models and to investigate annulus fibrosus damage mechanic...

متن کامل

Modeling shear behavior of the annulus fibrosus.

Modeling the mechanical properties of the annulus fibrosus has two distinct challenges: the complex loading state experienced in vivo and the anisotropic, nonlinear nature of the tissue. Previous efforts to model the annulus fibrosus have not considered shear data in the analysis, yet the shear response may be critical to understanding tissue behavior and damage. In this study, we compared four...

متن کامل

The effects of needle puncture injury on microscale shear strain in the intervertebral disc annulus fibrosus.

BACKGROUND CONTEXT Needle puncture of the intervertebral disc (IVD) is required for delivery of therapeutic agents to the nucleus pulposus and for some diagnostic procedures. Needle puncture has also been implicated as an initiator of disc degeneration. It is hypothesized that needle puncture may initiate IVD degeneration by altering microscale mechanical behavior in the annulus fibrosus (AF). ...

متن کامل

Optical coherence tomographic elastography technique for measuring deformation and strain of atherosclerotic tissues.

OBJECTIVES To evaluate optical coherence tomographic elastography as a method for assessing the elastic properties of atherosclerotic plaque and the parameters that influence interpretation. METHODS Phantoms and aorta were examined in vitro to quantify speckle modulation and measure the displacement and strain maps. A correlation method was used as a speckle tracking technique for measuring a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 41 13  شماره 

صفحات  -

تاریخ انتشار 2016