Correlates of peak expiratory flow lability in elderly persons.
نویسندگان
چکیده
OBJECTIVE To determine the correlates of the lability of peak expiratory flow (PEF) in the elderly. METHODS A community sample of 4,581 persons > or = 65 years old from the Cardiovascular Health Study completed an asthma questionnaire and underwent spirometry. During a follow-up examination of the cohort, 1,836 persons agreed to measure PEF at home twice daily for 2 weeks, and 90% successfully obtained at least 4 days of valid measurements. PEF lability was calculated as the highest daily (PEF maximum - PEF minimum)/mean PEF. RESULTS Mean PEF measured at home was accurate when compared to PEF determined by spirometry in the clinic. Mean PEF lability was 18% in those with current asthma (n = 165) vs 12% in healthy nonsmokers (upper limit of normal, 29%). Approximately 26% of those with asthma and 14% of the other participants had abnormally high PEF lability (> 29%). After excluding participants with asthma, other independent predictors of high PEF lability included black race, current and former smoking, airway obstruction on spirometry, daytime sleepiness, recent wheezing, chronic cough, emphysema, and wheezing from lying in a supine position. Despite having a lower mean PEF, those reporting congestive heart failure (n = 82) did not have significantly higher PEF lability. CONCLUSIONS Measurement of PEF lability at home is highly successful in elderly persons. PEF lability > or = 30% is abnormal in the elderly and is associated with asthma.
منابع مشابه
Peak flow lability: association with asthma and spirometry in an older cohort.
OBJECTIVE To determine the success rate and correlates of ambulatory peak expiratory flow (PEF) monitoring in an epidemiologic study. DESIGN An observational survey. SETTING Several communities in California. PARTICIPANTS We studied 1,223 nonsmoking men and women (mean age, 66 years) from an established cohort. OUTCOME MEASURES A standard respiratory symptoms and diagnoses questionnaire...
متن کاملPeak Expiratory Flow Rate in Healthy Children from Tehran
Background: Measuring peak expiratory flow rate has been suggested as an important tool in asthma management by all international guidelines. Objective: Studies on various populations have shown considerable variations in normal values of peak expiratory flow rate. Since reference standards for Iranian children are not available, the present study was performed to establish these standards. Me...
متن کاملReporting peak expiratory flow in older persons.
BACKGROUND Peak expiratory flow ("peak flow") predicts important outcomes in older persons. Nevertheless, its clinical application is uncertain because prior strategies for reporting peak flow may not be valid. We thus determined the frequency distribution of peak flow by the conventional strategy of percent predicted (%predicted) and by an alternative method termed standardized residual (SR) p...
متن کاملPeak expiratory flow rate in elderly Malaysians.
An epidemiological survey was conducted among 1,414 healthy ambulatory elderly persons aged 55 years and above in the Kuala Langat district, Selangor. The relationship between peak expiratory flow rate (PEFR), demographic variables, socioeconomic status, smoking, alcohol use and respiratory symptoms were examined. The peak expiratory flow declined with age and were lower in women of all ages. S...
متن کاملNormal measurement of peak expiratory Flow rate in the high school children in Babol, north of Iran
Background: Peak Expiratory Flow Rate (PEFR) is recommended as a tool for control of asthma. The purpose of this study was to determine the normal value of PEFR in the healthy high school children in Babol, Iran. Methods: This study was conducted on 470 healthy high school children (285 girls, 185 boys with the age between 14-18 years). For the determination of PEFR we used Mini Wright Peak Flo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 120 6 شماره
صفحات -
تاریخ انتشار 2001