Improved lesion detection from spatially adaptive, minimally complex, Pixon reconstruction of planar scintigraphic images.

نویسندگان

  • Carl A Wesolowski
  • Amos Yahil
  • Richard C Puetter
  • Paul S Babyn
  • David L Gilday
  • Mustafa Z Khan
چکیده

Pixon noise reduction was applied to 18 planar images, six each from 99mTc-methylene diphosphonate (99mTc-MDP), 67Ga citrate (67Ga), and (123)I-metaiodobenzylguanidine ((123)I-MIBG) studies. Pixon processing increased patient signal-to-noise ratio, 6.8-11.8 fold. Three specialists preferred processed images 44 of 54 times with good agreement (87%). Most (9/10, p<0.02) of the null and negative preferences were from (123)I-MIBG studies. Inter-rater association was shown for 1-4 scale rated artifact p<0.1, noise p<0.01 and lesion detection p<0.05. Pixon images had superior lesion detection ability, p<0.02, and noise levels, p<0.02 and no statistically significant change in artifacts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Salt and Pepper Noise Removal using Pixon-based Segmentation and Adaptive Median Filter

Removing salt and pepper noise is an active research area in image processing. In this paper, a two-phase method is proposed for removing salt and pepper noise while preserving edges and fine details. In the first phase, noise candidate pixels are detected which are likely to be contaminated by noise. In the second phase, only noise candidate pixels are restored using adaptive median filter. In...

متن کامل

Statistically Based, Spatially Adaptive Noise Reduction of Planar Nuclear Studies

The data-driven Pixon noise-reduction method is applied to nuclear studies. By using the local information content, it preserves all statistically justifiable image features without generating artifacts. Statistical measures provide the user a feedback to judge if the processing parameters are optimal. The present work focuses on planar nuclear images with known Poisson noise characteristics. I...

متن کامل

Clinical Validation of a Pixon-Based Reconstruction Method Allowing a Twofold Reduction in Planar Images Time of 111In-Pentetreotide Somatostatin Receptor Scintigraphy

OBJECTIVE The objective of this study was to evaluate the diagnostic efficacy of Pixon-based reconstruction method on planar somatostatin receptor scintigraphy (SRS). METHODS All patients with neuroendocrine tumors (NETs) disease who were referred for SRS to our department during 1-year period from January to December 2015 were consecutively included. Three nuclear physicians independently re...

متن کامل

Improvement in DMSA imaging using adaptive noise reduction: an ROC analysis.

Dimercaptosuccinic acid imaging is the 'gold standard' for the detection of cortical defects and diagnosis of scarring of the kidneys. The Siemens planar processing package, which implements adaptive noise reduction using the Pixon algorithm, is designed to allow a reduction in image noise, enabling improved image quality and reduced acquisition time/injected activity. This study aimed to estab...

متن کامل

A New Approach for Quantitative Evaluation of Reconstruction Algorithms in SPECT

ABTRACT Background: In nuclear medicine, phantoms are mainly used to evaluate the overall performance of the imaging systems and practically there is no phantom exclusively designed for the evaluation of the software performance.  In this study the Hoffman brain phantom was used for quantitative evaluation of reconstruction techniques. The phantom is modified to acquire t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 2005