Improving qPCR efficiency in environmental samples by selective removal of humic acids with DAX-8.
نویسندگان
چکیده
Quantitative PCR is becoming the method of choice for the detection of pathogenic microorganisms and other targets in the environment. A major obstacle when amplifying DNA is the presence of inhibiting substances like humic acids that decrease the efficiency of PCR. We combined the polymeric adsorbent Supelite™ DAX-8 with a large-volume (10 mL) nucleic acid extraction method to decrease the humic acid content prior to qPCR quantification in water samples. The method was tested by spiking with humic acid standards and the bacterial surrogate Acinetobacter baylyi ADP1. Improvements in qPCR detection of ADP1 after application of DAX-8 resin (5 and 10 w/v%) were compared with the effects of added bovine serum albumin (BSA) (50, 100 and 200 ng/μL). Both additions improved detection of ADP1 by counteracting inhibitory effects. There were no changes in mean cycle threshold difference (ΔC(T)) after application of DAX-8 compared to the control despite some loss of DNA, whereas significant increases occurred for BSA, irrespective of BSA concentration applied. The use of DAX-8 leads to an increase in qPCR amplification efficiency in contrast to BSA. The commonly used method to calculate genomic sample concentrations by comparing measured CT values relative to standard curves is only valid if amplification efficiencies of both are sufficiently similar. DAX-8 can provide this efficiency by removing humic acids permanently from nucleic acid extracts and has the potential to significantly increase the reliability of reported non-detects and measured results obtained by qPCR in environmental monitoring.
منابع مشابه
Humic acid removal from aqueous solutions by peroxi-electrocoagulation process
Background: Natural organic matter is the cause of many problems associated with water treatment such as the presence of disinfection by-products (DBPs) and membrane fouling during water filtration. In this study, the performance of the peroxi-electrocoagulation process (PEP) was investigated for the removal of humic acids (HAs) from aqueous solutions. Methods: PEP was carried out for the remov...
متن کاملThe Effect of Nitrate as a Radical Scavenger for the Removal of Humic Acid from Aqueous Solutions by Electron Beam Irradiation
Introduction: Humic acids have adverse effects on the water quality, then should be removed from water resources. The aim of this study was to evaluate the effect of nitrate as a radical scavenger for removal of humic acid from aqueous solutions by electron beam irradiation. Materials and Methods: In this study, after preparation of stock humic acid solution in alkaline condition, different con...
متن کاملبررسی کارایی پرتوهای پرانرژی الکترونی در حذف اسید هیومیک از محلول های آبی
Background: Humic acids (HAs) have adverse effects on the environment; therefore, they should be removed from the water and wastewater. The aim of this study was to evaluate the efficiency of the electron beam irradiation for removal of humic acid from aqueous solutions. Methods: Humic acid was purchased from Sigma-Aldrich Company. After preparation of stock solution in alkaline condition, d...
متن کاملThe simultaneous removal of turbidity and humic substances from water using the enhanced coagulation process
This study aimed to investigate the efficiency of the enhanced coagulation (EC) process for the simultaneous removal of turbidity and humic substances (HS) from raw water from the Sanandaj Water Treatment Plant (SWTP). This study was conducted on a laboratory scale using a jar test device and ferric chloride (FeCL3) as the coagulant. Accordingly, the effects of pH and coagulant dosag...
متن کاملThe Effect of Different Electrodes on Humic Acid Removal by Electrocoagulation
The present study is about the reduction of humic acids (HA) by electrocoagulation (EC) method. Undesirable color, odor, taste, reacting with chlorine to produce toxic materials in water, and making a complex with heavy metal ions are some unfavorable environmental consequences of HA. Platinum and graphite as anode electrodes and platinum, titanium, and aluminum as cathode electrodes were used ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of microbiological methods
دوره 85 1 شماره
صفحات -
تاریخ انتشار 2011