A Novel Technique for Functional MRI in Regions of Magnetic Field Inhomogeneity – Z-shim Asymmetric Spin-Echo (ASE) Spiral
نویسندگان
چکیده
K. D. Brewer, R. C. D'Arcy, C. V. Bowen, and S. D. Beyea Department of Physics, Dalhousie University, Halifax, Nova Scotia, Canada, Institute for Biodiagnostics (Atlantic), National Research Council of Canada, Halifax, Nova Scotia, Canada, Departments of Psychology and Radiology, Dalhousie University, Halifax, Nova Scotia, Canada, Departments of Physics, Radiology and Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
منابع مشابه
Simultaneous acquisition of gradient-echo and asymmetric spin-echo for single-shot z-shim: Z-SAGA.
This article describes the Z-SAGA pulse sequence, a technique for recovering susceptibility losses in EPI images for neuroimaging applications. The pulse sequence is based on an asymmetric spin echo EPI sequence and acquires a gradient echo image and an asymmetric spin echo image in a single shot. For one of the images, a z-shim gradient pulse is applied to compensate for susceptibility-related...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملMultiple gradient- and spin-echo EPI acquisition technique with z-shimming to compensate for susceptibility-induced off- resonance effects
INTRODUCTION – Images obtained with gradient-echo echo planar imaging (GRE-EPI) suffer from magnetic field variations within the brain, such as in regions adjacent to air-tissue interfaces. In these regions, magnetic field inhomogeneities cause spins to dephase more rapidly, resulting in signal dropouts. Thus, conventional GRE-EPI pulse sequences used for dynamic susceptibility-contrast perfusi...
متن کاملVolumetric R2 * mapping using z-shim multi-echo gradient echo imaging.
PURPOSE To introduce macroscopic B0 field inhomogeneity-compensated volumetric R2 * mapping method with a three-dimensional (3D) z-shim multi-echo acquisition. METHODS The proposed z-shim sequence acquired conventional and z-shimmed echoes alternately with bipolar readout gradients. A constant-valued z-shim gradient was applied prior to each negative readout gradient lobe. A phase combination...
متن کاملReducing susceptibility artifacts in fMRI using volume-selective z-shim compensation.
Susceptibility-induced magnetic field gradients (SFGs) can result in severe signal loss in the orbitofrontal cortex (OFC) in gradient-echo-based functional MRI (fMRI) studies. Although conventional z-shim techniques can effectively recover the MRI signal in this region, the substantial penalty in imaging time hampers their use in routine fMRI studies. A modified z-shim technique with high imagi...