Two-site time-resolved immunofluorometric assay of human insulin.
نویسندگان
چکیده
We describe a two-site "sandwich"-type time-resolved immunofluorometric assay for human insulin, based on use of two monoclonal antibodies with different specificities. The first antibody is immobilized on the surface of microtiter plate strip wells, the other is labeled with Eu3+. Serum samples can be assayed with one incubation step; two incubation steps are required when plasma samples are assayed. After the immunoreactions are complete, the bound fraction of Eu3+-label is quantified by dissociating it in a fluorescence-enhancement solution and measuring its fluorescence with a fluorometer with time-resolution. The sensitivity of the assay is 0.24 micro-int. units/mL. The standard curve is linear from 0.24 to 2400 micro-int. units/mL.
منابع مشابه
Development of time-resolved immunofluorometric assay of vascular permeability factor.
We describe a two-site time-resolved immunofluorometric assay for guinea pig vascular permeability factor (VPF) for quantifying VPF in different biological fluids. Antibody against the carboxy terminus (C-IgG) is immobilized on microtiter wells, and antibody against the amino terminus (N-IgG) is labeled with Eu(3+)-chelate. Line 10 tumor culture medium, known to be rich in VPF, is assayed in a ...
متن کاملCyclosporlne Concentrations In Plasma at 37#{176}C Are Not PredIctable from ConcentratIons Measured In Whole Blood at Room Temperature, Paula Suit,
CLINICALCHEMISTRY, Vol.34, No. 3, 1988 597 References 1. Toivonen E, Hemmila I, Marniemi J, et al. Two-site timeresolved immtmofluorometric assay of human insulin. Clin Chem 1986;32:637-40. 2. BadorR, D#{233}chaud H, Claustrat F, DeauzmgesC. Europium and samarium as labels in time-resolved immunofluorometric assay of follitropin. Clin Chem 1987;33:48-51. 3. Leery JJ, Brigati DJ, Ward DC. Rapida...
متن کاملTime-resolved immunofluorometric assay of human growth hormone.
We describe a time-resolved immunofluorometric assay (trIFMA) for human growth hormone (hGH), in which monoclonal antibody (mAb)-coated microtiter strip wells and a europium (Eu) chelate-labeled mAb are used. We compare the new trIFMA, in which two mAbs are used, with an immunoradiometric assay (IRMA) in which polyclonal antibodies are used. Serum samples (n = 185) from 36 children with various...
متن کاملSomatotropin as measured by a two-site time-resolved immunofluorometric assay.
To date, many of the current criteria for diagnosis of somatotropin (growth hormone, GH) deficiency have been based upon measurement of this hormone by competitive radioimmunoassay (RIA) with use of polyclonal antibodies. In recent years, however, the development of hybridoma technology has led to the generation of various monoclonal antibodies (Mabs) to GH with different affinities and epitope...
متن کاملMeasurement of corticotropin in unextracted plasma: comparison of a time-resolved immunofluorometric assay and an immunoradiometric assay, with use of the same monoclonal antibodies.
We describe a time-resolved immunofluorometric assay (IFMA) for corticotropin in unextracted human plasma, based on the use of two monoclonal antibodies: europium-labeled antibody 1A12 and antibody 2A3 coated onto microtiter wells. We compared the results of this assay with those of an immunoradiometric assay (IRMA) performed with the same antibodies working ranges (CV less than 10%) were 25 to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 32 4 شماره
صفحات -
تاریخ انتشار 1986