Experimental Investigation on Beat Transfer in the Manifolds of Refrigerating Compressors

نویسندگان

  • Y. Gu
  • Y. Wu
چکیده

In this study, a review and discussion has been made on the research work of heat transfer in manifolds previously done. Since it is difficult to determine the heat transfer coefficients in different areas of a suction or discharge chamber by using conventional methods, the mass transfer analogy -sublimation of naphthalene has been used to develop the heat transfer correlations for the four areas in a suction chamber. The mass transfer experiments were carried out on a model under the stable flow conditions with air as the medium. The correctness of the correlations has been verified through the measurement of U.e average heat transfer coefficient in the chamber. The maximum deviation of heat transfer coefficients measured from the correlations is within ±10%. project supported by the Science Fund of the Chinese Academy of Sci~nces 175 INTRODUCTION Since the 1970s, some work have been done to determine the manifold heat transfer coefficients in refrigerating compressors. J. M. Hughes (1) and Dang Jinquan (2) respectively presented the following heat transfer correlations for the valve passage, the suction chamber and the discharge chamber that they have used in their heat transfer experiments~ Hughes: Valve Passage o.i>3 0.6 Nu "" 1.48Re Pr

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Investigation in Pool Boiling Heat Transfer of Pure/Binary Mixtures and Heat Transfer Correlations

Nucleate pool boiling heat transfer coefficient have been experimentally measured on a horizontal rod heater for various liquid binary mixtures. Measurements are based on more than three hundred data points on a wide range of concentrations and heat fluxes. In this investigation, it has been confirmed that the heat transfer coefficient in boiling solutions are regularly less than those in p...

متن کامل

Comparison of Performances Between R404A and AZ50 Used in Commercial Refrigeration

Denis CLODIC Centre d'Energetique ·Ecole des Mines de Paris 60, boulevard Saint-Michel· F • 75272 PARIS Cedex 06 A test bench has been developed consisting in an open display-case and a refrigerating system composed mainly of four hermetic compressors, an air cross-current condenser and an evaporator. The evaporating temperature of -40°C allows to keep the temperature of the products at ·18°C f...

متن کامل

Experimental investigation of the effect of suspended nanoparticles into conventional fluid on the heat transfer improvement

Heat Transfer has special importance in engineering applications. So, researchers have suggested different new idea to increase heat transfer and using nanofluid is one of these methods In recent years, new methods have been used. One of these methods is the use of nanofluids, ., because nanofluids have higher heat transfer potential than base conventional fluids. In this investigation effect o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014