An injection method for measuring the carbon isotope content of soil carbon dioxide and soil respiration with a tunable diode laser absorption spectrometer.

نویسندگان

  • Andrew B Moyes
  • Andrew J Schauer
  • Rolf T W Siegwolf
  • David R Bowling
چکیده

We present a novel technique in which the carbon isotope ratio (delta(13)C) of soil CO(2) is measured from small gas samples (<5 mL) injected into a stream of CO(2)-free air flowing into a tunable diode laser absorption spectrometer (TDL). This new method extends the dynamic range of the TDL to measure CO(2) mole fractions ranging from ambient to pure CO(2), reduces the volume of sample required to a few mL, and does not require field deployment of the instrument. The measurement precision of samples stored for up to 60 days was 0.23 per thousand. The new TDL method was applied with a simple gas well sampling technique to obtain and measure gas samples from shallow soil depth increments for CO(2) mole fraction and delta(13)C analysis, and subsequent determination of the delta(13)C of soil-respired CO(2). The method was tested using an artificial soil system containing a controlled CO(2) source and compared with an independent method using the TDL and an open soil chamber. The profile and chamber estimates of delta(13)C of an artificially produced CO(2) flux were consistent and converged to the delta(13)C of the CO(2) source at steady state, indicating the accuracy of both methods under controlled conditions. The new TDL method, in which a small pulse of sample is measured on a carrier gas stream, is analogous for the TDL technique to the development of continuous-flow configurations for isotope ratio mass spectrometry. While the applications presented here are focused on soil CO(2), this new TDL method could be applied in a number of situations requiring measurement of delta(13)C of CO(2) in small gas samples with ambient to high CO(2) mole fractions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term field performance of a tunable diode laser absorption spectrometer for analysis of carbon isotopes of CO2 in forest air

Tunable diode laser absorption spectrometry (TDLAS) is gaining in popularity for measuring the mole fraction [CO2] and stable isotopic composition (δ13C) of carbon dioxide (CO2) in air in studies of biosphere-atmosphere gas exchange. Here we present a detailed examination of the performance of a commercially-available TDLAS located in a high-altitude subalpine coniferous forest (the Niwot Ridge...

متن کامل

b404552c doc..b404552c chapter .. Page772

The performance of a home-built tunable diode laser (TDL) spectrometer, aimed at multi-line detection of carbon dioxide, has been evaluated and optimized. In the regime of the (301)III / (000) band of CO2 around 1.6 mm, the dominating isotope species CO2, CO2, and 12C18O16O were detected simultaneously without interference by water vapor. Detection limits in the range of few ppmv were obtained ...

متن کامل

Assessment the effect of Slope aspect and position on some soil microbial indices in rangeland and forest

Extended abstract   Introduction   Topography is one of the effective factors in soil formation and development. Topographical features such as slope aspect and position, by affecting soil temperature, evaporation capacity, soil moisture content, soil organic matter, precipitation, movement, and accumulation of soil solution can impress soil microbial properties. For investigating the ...

متن کامل

A Compact Tunable Diode Laser Absorption Spectrometer to Monitor CO2 at 2.7 μm Wavelength in Hypersonic Flows

Since the beginning of the Mars planet exploration, the characterization of carbon dioxide hypersonic flows to simulate a spaceship's Mars atmosphere entry conditions has been an important issue. We have developed a Tunable Diode Laser Absorption Spectrometer with a new room-temperature operating antimony-based distributed feedback laser (DFB) diode laser to characterize the velocity, the tempe...

متن کامل

Stable isotope analysis using tunable diode laser spectroscopy.

Measurements of ratios of stable isotopes are used in such diverse fields as petroleum prospecting, medical diagnostics, and planetary exploration. The narrow emission linewidth available from tunable diode lasers permits high-resolution infrared absorption measurements of closely spaced isotopic rovibrational lines. Our dual beam spectrometer uses the sweep integration technique in a spectral ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rapid communications in mass spectrometry : RCM

دوره 24 7  شماره 

صفحات  -

تاریخ انتشار 2010