BACKGROUND The sniffing position (neck flexion by head elevation and head extension) is commonly used for insertion of a laryngeal mask airway. However, the appropriate degrees of head elevation and head extension are unclear. In the present study, the success rate of ProSeal™ laryngeal mask airway (LMA ProSeal) insertion using two degrees of head elevation was evaluated. METHODS This prospective randomized, controlled study included 80 adult patients aged 18 to 90 years. In the 3 cm (n = 40) and 6 cm (n = 40) groups, the LMA ProSeal was inserted while the head was elevated 3 cm and 6 cm, respectively, using a pillow of the corresponding height. The success rate, and incidence of blood staining on cuff, sore throat and hoarseness were assessed. The alignments of laryngeal and oral axes were also evaluated. RESULTS The first attempt success rate was higher in the 3 cm than the 6 cm group (87 % vs. 60 %, P = 0.014). In 86 % of patients in the 6 cm group and 50 % of patients in the 3 cm group in whom the second attempt failed, the third insertion attempt was successful by using a pillow height of the opposite group. The alignments of the two axes were not different between the two groups (P > 0.05). CONCLUSIONS The first attempt success rate of ProSeal laryngeal mask insertion was higher with 3 cm than 6 cm head elevation in adult patients. TRIAL REGISTRATION Identifiers: NCT02058030 (08/05/2015), Unique Protocol ID: phdkim1.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Randomized crossover comparison of the proseal with the classic laryngeal mask airway in unparalysed anaesthetized patients.

BACKGROUND The ProSeal is a wire-reinforced laryngeal mask airway with an additional drain tube that leads to the distal tip of the laryngeal cuff. The design should improve the seal with the larynx. METHODS The ProSeal and classic laryngeal mask airways were compared in 180 patients in a randomized crossover study. Patients were anaesthetized without neuromuscular blocking drugs. RESULTS T...

متن کامل

Comparison of the Incidence of Sore Throat and Hemodynamic Changes in ‎Airway Management by Macintosh, Glideoscope Laryngoscope and ‎Laryngeal Mask Airway Techniques: Randomized Controlled Trial

Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway  techniques in elective surg...

متن کامل

Randomized crossover comparison of ProSeal Laryngeal Mask Airway with Laryngeal Tube Sonda during anaesthesia with controlled ventilation.

BACKGROUND The Laryngeal Tube Sonda (LTS) is a supraglottic airway which, like the ProSeal Laryngeal Mask Airway (PLMA), incorporates a drain tube. We compared the performances of LTS and PLMA during controlled ventilation anaesthesia. METHODS The devices were studied in 32 ventilated patients by randomized crossover trial. Primary outcome was airway seal pressure. Secondary outcomes included...

متن کامل

Comparison between i-gel airway an the proseal laryngeal mask airway in pediatric patients undergoing general anesthesia

Background The I-gel airway is a new supraglottic airway device without an inflatable cuff. In this study we compare the efficacy of the I-gel airway with the Proseal laryngeal mask airway (p-LMA) in children undergoing elective surgery under general anesthesia without use of muscle relaxants. Methods Eighty children, one to twelve years of age posted for elective surgery under general anesthes...

متن کامل

A multicenter study comparing the ProSeal and Classic laryngeal mask airway in anesthetized, nonparalyzed patients.

BACKGROUND The laryngeal mask airway ProSeal (PLMA), a new laryngeal mask device, was compared with the laryngeal mask airway Classic (LMA) with respect to: (1) insertion success rates and times; (2) efficacy of seal; (3) fiberoptically determined anatomic position; (4) orogastric tube insertion success rates and times; (5) total intraoperative complications; and (6) postoperative sore throat i...