Treatment Planning Methods in High Dose Rate Interstitial Brachytherapy of Carcinoma Cervix: A Dosimetric and Radiobiological Analysis
نویسندگان
چکیده
Treatment planning is a trial and error process that determines optimal dwell times, dose distribution, and loading pattern for high dose rate brachytherapy. Planning systems offer a number of dose calculation methods to either normalize or optimize the radiation dose. Each method has its own characteristics for achieving therapeutic dose to mitigate cancer growth without harming contiguous normal tissues. Our aim is to propose the best suited method for planning interstitial brachytherapy. 40 cervical cancer patients were randomly selected and 5 planning methods were iterated. Graphical optimization was compared with implant geometry and dose point normalization/optimization techniques using dosimetrical and radiobiological plan quality indices retrospectively. Mean tumor control probability was similar in all the methods with no statistical significance. Mean normal tissue complication probability for bladder and rectum is 0.3252 and 0.3126 (P = 0.0001), respectively, in graphical optimized plans compared to other methods. There was no significant correlation found between Conformity Index and tumor control probability when the plans were ranked according to Pearson product moment method (r = -0.120). Graphical optimization can result in maximum sparing of normal tissues.
منابع مشابه
Study of dosimetric and spatial variations due to applicator positioning during inter-fraction high-dose rate brachytherapy in the treatment of carcinoma of the cervix: A three dimensional dosimetric analysis
Background: This study evaluates dosimetric and spatial variations in inter–fraction applicator positioning in high dose rate (HDR) brachytherapy. Materials and Methods: This study includes 25 retrospective patients of carcinoma of the cervix. Each patient received 5 fractions of HDR intracavitary brachytherapy. High Risk-Clinical Target Volume (HR-CTV) were drawn on CT images. First impl...
متن کاملDetermination of Dosimetric Characteristics of IrSeed 125I Brachytherapy Source
Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...
متن کاملA detailed dosimetric comparison between manual and inverse plans in HDR intracavitary/interstitial cervical cancer brachytherapy
PURPOSE The purpose of this study was to compare two inverse planning algorithms for cervical cancer brachytherapy and a conventional manual treatment planning according to the MUW (Medical University of Vienna) protocol. MATERIAL AND METHODS For 20 patients, manually optimized, and, inversely optimized treatment plans with Hybrid Inverse treatment Planning and Optimization (HIPO) and with In...
متن کاملA patient‐based dosimetric study of intracavitary and interstitial brachytherapy in advanced stage carcinoma of the cervix
Intracavitary brachytherapy (ICBT) and interstitial brachytherapy (IB) techniques are commonly practiced for treating carcinoma of the cervix, either alone or in combination with external beam radiotherapy. Both these brachytherapy techniques have their own advantages and limitations in terms of tumor coverage and normal tissue sparing. Limited studies have been reported comparing the dosimetri...
متن کاملDosimetric comparison of various optimization techniques for high dose rate brachytherapy of interstitial cervix implants
HDR brachytherapy treatment planning often involves optimization methods to calculate the dwell times and dwell positions of the radioactive source along specified afterloading catheters. The purpose of this study is to compare the dose distribution obtained with geometric optimization (GO) and volume optimization (VO) combined with isodose reshaping. This is a retrospective study of 10 cervix ...
متن کاملذخیره در منابع من