BGO readout with photodiodes as a soft gamma-ray detector at −30◦C

نویسندگان

  • T. Nakamoto
  • Y. Fukazawa
  • T. Ohsugi
  • J. Kataoka
چکیده

BGO is expected to be plausible devices for soft gamma-ray detectors, because of a high detection efficiency for soft gamma-rays. Here we report on the good performance of BGO readout with PIN-photodiode or avalanche photodiode as a soft gamma-ray detector. We confirmed that the signal output of BGO becomes comparable to that of GSO when it is readout with photodiodes due to better matching between emission wavelength of BGO and quantum efficiency of photodiode. The energy resolution of 6.2% and 3.4% for 662 keV and 1836 keV, respectively, gammarays at -30 ◦C is obtained with the combination of the 5 × 5 × 5 mm3 cube BGO and the Hamamatsu avalanche photodiode (APD) S8664-55. In this combination, the lowest detectable energy is found to be ∼10 keV. These performances are better than that obtained with Photomultiplier tube (PMT), and our results increase many possible applications of BGO readout with photodiodes as soft gamma-ray detectors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Photodiode Readout Scheme for High Resolution Scintillation Crystal Arrays

We are exploring the possibility of using PIN photodiodes to readout the scintillation crystals used in Positron Emission Tomography (PET) detector designs. Solid state photodetectors typically have a lower signal to noise ratio than photomultiplier tubes (PMTs). However, they have the advantage of compactness, and, thus, scintillation crystal readout schemes not available to PMTs because of th...

متن کامل

Investigation of a New Readout Scheme for High Resolution Scintillation Crystal Arrays Using Photodi - Nuclear Science, IEEE Transactions on

We are exploring the possibility of using PIN photodiodes to readout the scintillation crystals used in Positron Emission Tomography (PET) detector designs. Semiconductor photodetectors typically have a lower signal to noise ratio than photomultiplier tubes (PMTs). However, they have the advantage of compactness, and, thus, scintillation crystal readout schemes not available to PMTs because of ...

متن کامل

Recent progress of avalanche photodiodes in high-resolution X-rays and γ-rays detection

We have studied the performance of large area avalanche photodiodes (APDs) recently developed by Hamamatsu Photonics K.K, in high-resolution X-rays and γrays detections. We show that reach-through APD can be an excellent soft X-ray detector operating at room temperature or moderately cooled environment. We obtain the best energy resolution ever achieved with APDs, 6.4 % for 5.9 keV X-rays, and ...

متن کامل

طراحی، شبیه‌سازی و ساخت یک نمونه اتاقک گازی پرتو ایکس حساس به موقعیت

In this paper a one dimentional position-sensitive X-ray gas detector has been designed, simulated and constructed based on Multi Wire Proportional Chamber (MWPC) with delay line position readout. These kinds of detectors are useful in soft X-ray imaging and are capable of being extended to two dimensions position readout easily. The position resolution of this detector is estimated to be 230µm...

متن کامل

Design and construction of the Mini-Calorimeter of the AGILE satellite

AGILE is a small space mission of the Italian Space Agency (ASI) devoted to gamma-ray and hard-X astrophysics, successfully launched on April 23 2007. The AGILE Payload is composed of three instruments: a gamma-ray imager based on a tungsten-silicon tracker (ST), for observations in the gamma ray energy range 30 MeV 50 GeV, a Silicon based X-ray detector, SuperAGILE (SA), for imaging in the ran...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004