Global Extrema in Traveltime Tomography
نویسنده
چکیده
منابع مشابه
Global P and PP traveltime tomography: rays versus waves
S U M M A R Y This paper presents a comparison of ray-theoretical and finite-frequency traveltime tomography for compressional waves. Our data set consists of 86 405 long-period P and PP–P traveltimes measured by cross-correlation. The traveltime of a finite-frequency wave is sensitive to anomalies in a hollow banana-shaped region surrounding the unperturbed ray path, with the sensitivity being...
متن کاملOn Crosswell Traveltime Tomography
In this paper, we give a theoretical analysis of the crosswell traveltime tomography. In the single arrival case, we prove that the objective function is smooth, and every critical point is a kinematically correct velocity model. A numerical example is presented to demonstrate the properties we prove and the diierence between traveltime tomography and waveform inversion via the output least squ...
متن کاملDynamic ray tracing and traveltime corrections for global seismic tomography
We present a dynamic ray tracing program for a spherically symmetric Earth that may be used to compute Fréchet kernels for traveltime and amplitude anomalies at finite frequency. The program works for arbitrarily defined phases and background models. The numerical precisions of kinematic and dynamic ray tracing are optimized to produce traveltime errors under 0.1 s, which is well below the data...
متن کاملA Penalization-Regularization-Operator Splitting Method for Eikonal Based Traveltime Tomography
Abstract We propose a new methodology for carrying out eikonal-based traveltime tomography arising from important applications such as seismic imaging and medical imaging. The new method formulates the traveltime tomography problem as a variational problem for a certain cost functional explicitly with respect to both traveltime and sound speed. Furthermore, the cost functional is penalized to e...
متن کاملRay based tomography using residual Stolt migration
In complex areas, residual vertical movement is not an effective method to calculate traveltime errors for image domain tomography. By scanning over velocity ratios using residual Stolt migration, a different criteria for a coherent image can be defined, and a traveltime error approximated. The resulting traveltime errors are more accurate, therefore the tomography procedure is more robust than...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008