Determination of phosphorus in fertilizers by inductively coupled plasma atomic emission spectrometry.

نویسندگان

  • Wei Min Yang
  • Rhonda L Boles
  • Thomas P Mawhinne
چکیده

An inductively coupled plasma atomic emission spectrometry (ICP-AES) method was developed for the determination of phosphorus in fertilizers. Total phosphorus, direct extraction available phosphorus (EDTA), and water-soluble phosphorus, reported as phosphorus pentoxide (P205), in 15 Magruder check fertilizers were measured by ICP-AES, and the results were compared with those obtained by the AOAC official method. Five analytical wavelengths of phosphorus, 177.499, 178.287, 213.618, 214.914, and 253.565 nm, were tested for the determination of phosphorus in fertilizers, and their detection limits were obtained. Acid effects of perchloric acid and possible matrix effects of aluminum, calcium, magnesium, potassium, and sodium were negligible for phosphorus determination. Wavelength 213.618 nm was the best analytical wavelength for phosphorus determination by all 3 sample preparation methods for the selected Magruder fertilizers. The results demonstrated that the accuracy and precision of the ICP-AES method were comparable with those of the official methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry

In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...

متن کامل

Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression

A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...

متن کامل

Screening and Optimization of Microextraction of Pb(II) by Inductively Coupled Plasma-Atomic Emission Using Response Surface Methodology

Dispersive liquid–liquid microextraction (DLLME) combined with inductively coupled plasma-atomic emission spectrometry (ICP-AES) was applied for the determination of lead in different environmental water samples. Ammonium pyrrolidine dithiocarbamate (APDC), chloroform and ethanol were used as chelating agent, extraction solvent and disperser solvent, respectively. The effective parameters, such...

متن کامل

Microwave assisted digestion coupled with inductively coupled plasma optical emission spectrometry for determining element concentrations in halophytes

Introduction: This study was carried out to determine elements (Li, Na, K, Mg, Ca, Ba, B, Al, Si, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Ag and P) in the Suaeda vermiculata (S. vermiculata) and Suaeda aegyptiaca (S. aegyptiaca) in three different regions of Southern Iran using inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion. Materials and ...

متن کامل

Determination of Silicate in Seawater by Inductively Coupled Plasma Atomic Emission Spectrometry

Inductively Coupled Plasma Atomic Emission Spectrometry (ICP) was adopted for direct analysis of silicate in seawater, eliminating necessity for pre-treatment. Via this method, the determination of silicate is rapid and easy compared with conventional methods of colorimetry. In seawater analysis, a decrease of sensitivity of about 24% was observed due to interference by coexisting elements, mai...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of AOAC International

دوره 85 6  شماره 

صفحات  -

تاریخ انتشار 2002