Tidal volume lower than 6 ml/kg enhances lung protection: role of extracorporeal carbon dioxide removal.
نویسندگان
چکیده
BACKGROUND Tidal hyperinflation may occur in patients with acute respiratory distress syndrome who are ventilated with a tidal volume (VT) of 6 ml/kg of predicted body weight develop a plateau pressure (PPLAT) of 28 < or = PPLAT < or = 30 cm H2O. The authors verified whether VT lower than 6 ml/kg may enhance lung protection and that consequent respiratory acidosis may be managed by extracorporeal carbon dioxide removal. METHODS PPLAT, lung morphology computed tomography, and pulmonary inflammatory cytokines (bronchoalveolar lavage) were assessed in 32 patients ventilated with a VT of 6 ml/kg. Data are provided as mean +/- SD or median and interquartile (25th and 75th percentile) range. In patients with 28 < or = PPLAT < or = 30 cm H2O (n = 10), VT was reduced from 6.3 +/- 0.2 to 4.2 +/- 0.3 ml/kg, and PPLAT decreased from 29.1 +/- 1.2 to 25.0 +/- 1.2 cm H2O (P < 0.001); consequent respiratory acidosis (Paco2 from 48.4 +/- 8.7 to 73.6 +/- 11.1 mmHg and pH from 7.36 +/- 0.03 to 7.20 +/- 0.02; P < 0.001) was managed by extracorporeal carbon dioxide removal. Lung function, morphology, and pulmonary inflammatory cytokines were also assessed after 72 h. RESULTS Extracorporeal assist normalized Paco2 (50.4 +/- 8.2 mmHg) and pH (7.32 +/- 0.03) and allowed use of VT lower than 6 ml/kg for 144 (84-168) h. The improvement of morphological markers of lung protection and the reduction of pulmonary cytokines concentration (P < 0.01) were observed after 72 h of ventilation with VT lower than 6 ml/kg. No patient-related complications were observed. CONCLUSIONS VT lower than 6 ml/Kg enhanced lung protection. Respiratory acidosis consequent to low VT ventilation was safely and efficiently managed by extracorporeal carbon dioxide removal.
منابع مشابه
Smaller Tidal Volumes Improve ARDS Tidal Volume Lower Than 6 mL/kg Enhances Lung Protection: Role of Extracorporeal Carbon Dioxide Removal
Background: ARDSnet data reaffirm the practice of limiting tidal volume in patients with lung injury to 6 to 8 mL/kg of predicted body weight and limiting plateau pressures to avoid additional lung injury and excess mortality. Objective: To determine whether tidal volume <6 mL/kg is protective to the lungs and whether consequent respiratory acidosis can be managed by extracorporeal carbon dioxi...
متن کاملVentilator-induced lung injury: less ventilation, less injury.
THE publication of the seminal article by the Acute Respiratory Distress Syndrome Network (ARDSNet) on ventilation with lower tidal volumes in 2000 has changed the way we ventilate patients with ARDS. The use of low tidal volumes was the first therapy ever proven to improve survival of patients who were diagnosed with ARDS. Despite initial reluctance and even open criticism, clinicians across t...
متن کاملPumpless extracorporeal interventional lung assist in patients with acute respiratory distress syndrome: a prospective pilot study
INTRODUCTION Pumpless interventional lung assist (iLA) is used in patients with acute respiratory distress syndrome (ARDS) aimed at improving extracorporeal gas exchange with a membrane integrated in a passive arteriovenous shunt. In previous studies, feasibility and safety of the iLA system was demonstrated, but no survival benefit was observed. In the present pilot study we tested the hypothe...
متن کاملSafety and Efficacy of Combined Extracorporeal Co2 Removal and Renal Replacement Therapy in Patients With Acute Respiratory Distress Syndrome and Acute Kidney Injury: The Pulmonary and Renal Support in Acute Respiratory Distress Syndrome Study*
OBJECTIVE To assess the safety and efficacy of combining extracorporeal CO2 removal with continuous renal replacement therapy in patients presenting with acute respiratory distress syndrome and acute kidney injury. DESIGN Prospective human observational study. SETTINGS Patients received volume-controlled mechanical ventilation according to the acute respiratory distress syndrome net protoco...
متن کاملUltra-protective tidal volume: how low should we go?
Applying tidal volumes of less than 6 mL/kg might improve lung protection in patients with acute respiratory distress syndrome. In a recent article, Retamal and colleagues showed that such a reduction is feasible with conventional mechanical ventilation and leads to less tidal recruitment and overdistension without causing carbon dioxide retention or auto-positive end-expiratory pressure. Howev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 111 4 شماره
صفحات -
تاریخ انتشار 2009