A novel optoelectronic detector and improved flow analysis procedure for ammonia determination with Nessler's reagent.
نویسندگان
چکیده
This paper presents a simple, rapid and effective method for ammonia determination in a flow analysis regime using Nessler's reagent. The proposed modification of the common flow procedure results in the total elimination of the problem of precipitate deposition inside the flow manifold. The improved procedure has been adapted to a flow analysis system based on microsolenoid pumps combined with a dedicated optoelectronic detector fabricated specifically for this purpose. This photometric device has been constructed in the form of a compact flow-through cell (70 μL total volume and 1 cm optical pathlength) integrated with 395 nm LED emitter and 405 nm LED-based detector. The presented analytical system is capable of ammonia determination in the submillimolar concentration range with a detection limit below 0.1 mM and high throughput (over 20 injections per hour).
منابع مشابه
Continuous-flow Enzymatic Determination of Creatinine with Improved On-line Removal of Endogenous Ammonia
A new continuous-flow automated enzymatic method suitable for the direct determination of creatinine in physiological samples is described. The proposed system utilizes an on-line gas predialysis unit in conjunction with a flow-through enzyme reactor coil and a potentiometric ammonia detector. The enzyme reactor contains immobilized creatinine iminohydrolase (EC 3.5.4.21) which converts creatin...
متن کاملCcxc. a Modified Nessler's Reagent for the Micro-determination of Urea in Tungstic Acid Blood Filtrate. by John
متن کامل
A Photocatalytic Method for the Degradation of Pyrrolidine in Water
A method for the degradation of pyrrolidine in water is described. The method relaies on the photocatalytic degradation of pyrrolidine to CO2 and NH3 by UV irradiation and using titanium dixide semiconductor as a photocatalyst. Compared with direct photolysis, the semiconductor catalytic photolysis gave consistently higher degradation yields for pyrrolidine in water. T...
متن کاملSolvent extraction, spectrophotometric determination of copper (II) from environmental samples using o-methylphenyl thiourea as a novel reagent
A simple and rapid method has been developed for solvent extraction and spectrophotometric determination of copper (II) using o-methylphenyl thiourea (OMPT) as a sensitive reagent. The basis of proposed method is formation of copper (II)-OMPT complex. Copper (II) was extracted with 0.020 mol L-1 OMPT in chloroform from aqueous solution in 0.075 mol L-1 potassium iodate. The absorbance of comple...
متن کاملAutomation of flow injection gas diffusion-ion chromatography for the nanomolar determination of methylamines and ammonia in seawater and atmospheric samples
The automation and improved design and performance of Flow Injection Gas Diffusion-Ion Chromatography (FIGD-IC), a novel technique for the simultaneous analysis of trace ammonia (NH(3)) and methylamines (MAs) in aqueous media, is presented. Automated Flow Injection Gas Diffusion (FIGD) promotes the selective transmembrane diffusion of MAs and NH(3) from aqueous sample under strongly alkaline (p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 30 10 شماره
صفحات -
تاریخ انتشار 2014