Supporting Information Flow Induced Dispersion Analysis Rapidly Quantifies Proteins in Human Plasma Samples
نویسندگان
چکیده
In the FIDA experiment, a pressure gradient generates the flow resulting in a parabolic flow profile. The parabolic flow profile inside the capillary distorts the indicator zone resulting in a concentration gradient between the center and the periphery of the capillary (figure S1). Equation 5 in the main manuscript is valid provided there is sufficient time for radial diffusion, and that advective mass transport dominates over diffusive mass transport in the axial direction meaning that the contribution from axial diffusion is insignificant.1 A further prerequisite for applying the theory is that the width of the injected sample zone is sufficiently small compared to the width of the peak when detected.
منابع مشابه
Flow induced dispersion analysis rapidly quantifies proteins in human plasma samples.
Rapid and sensitive quantification of protein based biomarkers and drugs is a substantial challenge in diagnostics and biopharmaceutical drug development. Current technologies, such as ELISA, are characterized by being slow (hours), requiring relatively large amounts of sample and being subject to cumbersome and expensive assay development. In this work a new approach for quantification based o...
متن کاملRapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma
A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...
متن کاملRapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma
A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...
متن کاملDetermination of selenoprotein P in submicrolitre samples of human plasma using micro-affinity chromatography coupled with low flow ICP-MS
Se-containing proteins play an important role in human metabolic processes such as antioxidant action. However, speciation analysis of Se-containing proteins in biological samples is challenging because of their small amounts. In order to determine selenoprotein P (Sel-P) in human plasma, separation performance was compared between size exclusion chromatography and affinity chromatography. It w...
متن کاملBioactivity Determination of Recombinant lysostaphin Immobilized on Glass Surfaces Modified by Cold Atmospheric Plasma on Staphylococcus aureus
Introduction: Staphylococcus aureus is a source of nosocomial infections and one of the significant concerns in patients with indwelling devices. Lysostaphin is a bacterially produced endopeptidase with a unique activity on S. aureus. Plasma, the fourth state of the material, consists of charged ions, free electrons, and activated neutral species. Biomedical applications of cold plasma are rapi...
متن کامل