Cardiac dysrhythmias after transcatheter closure of ASD with Amplatzer device.

نویسندگان

  • Alpay Celiker
  • Süheyla Ozkutlu
  • Cemşit Karakurt
  • Tevfik Karagöz
چکیده

Transcatheter closure of atrial septal defect (ASD) has been used as an alternative to open heart surgery. Although transcatheter closure of ASD with the Amplatzer septal occluder is a safe and feasible method in pediatric patients, there is little published data on arrhythmia analysis following transcatheter device closure of secundum ASD. We evaluated cardiac dysrhythmias with 24-hour ambulatory electrocardiographic (ECG) monitoring after transcatheter closure of ASD with Amplatzer device. A total of 85 consecutive patients with ASD underwent transcatheter closure of secundum ASD with Amplatzer device between October 1998 and December 2003. The study involved 65 of these patients assessed by 24-hour ambulatory ECG monitoring. Seven patients were evaluated a second time by 24-hour monitorization. During the procedure, transient complete atrioventricular (AV) block was seen in two patients. One of them returned to normal sinus rhythm in catheterization lab and the other returned to normal sinus rhythm in two hours. Transient junctional rhythm was observed in another patient during the device placement. Twenty-four hour ambulatory ECG monitoring was performed on all patients after a mean four-month period (1-12 months). Holter recordings demonstrated rare supraventricular extrasystole in two patients, rare ventricular premature beats in two patients, and intermittent sinus arrest with sinus pause lasting <1.5 seconds in one patient, for a total of five patients (7.6%). In conclusion, dysrhythmias after transcatheter device closure of secundum ASD with Amplatzer device are rare and benign. We need further long-term follow-up to evaluate late dysrhythmias after the transcatheter device closure of secundum ASD.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder.

OBJECTIVES Amplatzer septal occluder (ASO)-associated cardiac perforation (CP) at our institution prompted this retrospective review. BACKGROUND Cardiac perforation is a rare complication after transcatheter atrial septal defect (ASD) closure. METHODS To identify CP after transcatheter ASD closure with ASO, cardiac events (CE) describing definite CP, hemopericardium, pericardial effusion, c...

متن کامل

Usefulness of transesophageal echocardiography for transcatheter closure of ostium secundum atrial septum defect with the amplatzer septal occluder.

BACKGROUND Transcatheter closure of ostium secundum atrial septum defect (ASDII) using the new self-centering occluder, Amplatzer Septal Occluder (ASO), has been well developed in recent years. We describe the importance and role of transesophageal echocardiography (TEE) in the selection and closure of such defects. METHODS Thirty patients referred for transcatheter closure of ASDII by ASO we...

متن کامل

Cardiac troponin I release after transcatheter atrial septal defect closure depends on occluder size but not on patient's age.

OBJECTIVE To examine whether transcatheter closure of secundum atrial septal defect (ASD) with the Amplatzer septal occluder leads to more myocardial injury in children than in adults. DESIGN In a prospective study with children and adults cardiac troponin I (cTnI) serum concentrations were determined by immunoassay (AxSYM, Abbott Laboratories) before, during, and up to 20 months after surgic...

متن کامل

CONGENITAL HEART DISEASE Cardiac troponin I release after transcatheter atrial septal defect closure depends on occluder size but not on patient’s age

Objective: To examine whether transcatheter closure of secundum atrial septal defect (ASD) with the Amplatzer septal occluder leads to more myocardial injury in children than in adults. Design: In a prospective study with children and adults cardiac troponin I (cTnI) serum concentrations were determined by immunoassay (AxSYM, Abbott Laboratories) before, during, and up to 20 months after surgic...

متن کامل

Relative Risk Factors for Cardiac Erosion Following Transcatheter Closure of Atrial Septal Defects: A Case-Control Study.

BACKGROUND Transcatheter closure of secundum atrial septal defects (ASD) using the Amplatzer septal occluder is generally safe and effective, but erosion into the pericardial space or aorta has been described. Although the absolute risk of this complication is low, there has been no assessment of relative risk factors. METHODS AND RESULTS All erosions reported to St. Jude Medical after ASD cl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Turkish journal of pediatrics

دوره 47 4  شماره 

صفحات  -