Immunoluminometric assay of chromogranin A in serum with commercially available reagents.
نویسندگان
چکیده
Chromogranin A (Cg A) is a useful marker of neuroendocrine neoplasia in humans. Here we describe an immunoluminometric assay (ILMA) for measuring Cg A in serum, with use of a new tube as a solid phase. The new tube has a large surface area and is coated with a polyclonal antibody. Optimized coating conditions provide a high IgG adsorption to the polystyrene wall. Serum is added to the coated tube and incubated for 2 h or overnight. After washing the tubes, acridinium ester-labeled monoclonal antibody against Cg A is added and incubation is continued for 2 h. The tubes are washed again and the bound luminescence is measured. The assay is very sensitive (detection limit 1 microgram/L, if 25 microL of serum is used), is specific for human Cg A, and offers a wide dynamic range (1-1000 micrograms/L). The range in healthy humans is 10-53 micrograms/L (median 30 micrograms/L). The correlation of serum Cg A to creatinine and parathyroid hormone is described. We also report the influence of intravenous calcium injection on Cg A concentrations in serum.
منابع مشابه
Parathyroid hormone assay in primary hyperparathyroidism: experiences with a radioimmunoassay based on commercially available reagents.
A radioimmunoassay is described for parathyroid hormone in human serum, in which commercially available reagents are used almost exclusively. This assay can be done by any laboratory with experience in radloimmunoassay. Thirty-two of thirty-three patients with surgically proven primary hyperparathyroidism had detectable concentrations of parathyroid hormone in their serum, and concentrations of...
متن کاملElectrophoretic determination of isoamylases in serum with commercially available reagents.
We describe and evaluate a method for determining isoamylases in serum. With this method, which involves conventional electrophoretic apparatus and commercially available reagents, seven isoenzymes can be resolved. The electrophoresis is performed in agarose gel, and isoenzymes are detected with a water-insoluble cross-linked starch polymer linked to a blue dye. The isoenzymes are quantified by...
متن کاملC-terminal parathyrin (parathyroid hormone) radioimmunoassay in serum with commercially available reagents.
We describe a sequential double-antibody assay for measuring C-terminal parathyrin in serum with commercially available reagents. Intact bovine hormone, used as a working standard, is iodinated by conventional Chloramine T procedures. The antibody affinity is characteristic of high affinity binding (1.4 to 1.6 x 10(10) L/mol of intact parathyrin). The antibody also cross reacts with a C-termina...
متن کاملEnzyme-linked immunosorbent assay for free thyroxin in human serum.
We describe a simple enzyme-linked immunosorbent assay (ELISA) in which microtiter plates are used for determining the free thyroxin concentration (FT4) in serum. Only commercially available chemicals and reagents are needed, including the antiserum. The working range is 1 to 60 ng/L. Turnaround time is about 4 h. Within-run coefficients of variation (CV) for FT4 concentrations of 9.0, 19.0, an...
متن کاملRadioimmunoassay of human homologous prolactin in serum with commercially available reagents.
A clincally useful and reproducible radioimmunoassay for human homologous prolactin, established with commercially available reagents, was studied and validated. We present detailed conditions for iodination and purification of labeled prolactin and the optimal conditions for the assay. By the method, we found values (microgram/liter) as follows for serum prolactin: normal men. 8.9 +/- 5.2 (mea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 38 11 شماره
صفحات -
تاریخ انتشار 1992