Total Ankle Arthroplasty Comparison of Extramedullary Versus Intramedullary Referencing for Tibial Component Alignment in
نویسندگان
چکیده
Background: The majority of total ankle arthroplasty (TAA) systems use extramedullary alignment guides for tibial component placement. However, at least 1 system offers intramedullary referencing. In total knee arthroplasty, studies suggest that tibial component placement is more accurate with intramedullary referencing. The purpose of this study was to compare the accuracy of extramedullary referencing with intramedullary referencing for tibial component placement in total ankle arthroplasty. Methods: The coronal and sagittal tibial component alignment was evaluated on the postoperative weight-bearing anteroposterior (AP) and lateral radiographs of 236 consecutive fixed-bearing TAAs. Radiographs were measured blindly by 2 investigators. The postoperative alignment of the prosthesis was compared with the surgeon’s intended alignment in both planes. The accuracy of tibial component alignment was compared between the extramedullary and intramedullary referencing techniques using unpaired t tests. Interrater and intrarater reliabilities were assessed with intraclass correlation coefficients (ICCs). Results: Eighty-three tibial components placed with an extramedullary referencing technique were compared with 153 implants placed with an intramedullary referencing technique. The accuracy of the extramedullary referencing was within a mean of 1.5 ± 1.4 degrees and 4.1 ± 2.9 degrees in the coronal and sagittal planes, respectively. The accuracy of intramedullary referencing was within a mean of 1.4 ± 1.1 degrees and 2.5 ± 1.8 degrees in the coronal and sagittal planes, respectively. There was a significant difference (P < .001) between the 2 techniques with respect to the sagittal plane alignment. Interrater ICCs for coronal and sagittal alignment were high (0.81 and 0.94, respectively). Intrarater ICCs for coronal and sagittal alignment were high for both investigators. Conclusions: Initial sagittal plane tibial component alignment was notably more accurate when intramedullary referencing was used. Further studies are needed to determine the effect of this difference on clinical outcomes and long-term survivability of the implants. Level of Evidence: Level III, retrospective comparative study.
منابع مشابه
Intramedullary versus extramedullary alignment of the tibial component in the Triathlon knee
BACKGROUND Long term survivorship in total knee arthroplasty is significantly dependant on prosthesis alignment. Our aim was determine which alignment guide was more accurate in positioning of the tibial component in total knee arthroplasty. We also aimed to assess whether there was any difference in short term patient outcome. METHOD A comparison of intramedullary versus extramedullary align...
متن کاملExtramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement
BACKGROUND In a standard total knee replacement, tibial component alignment is a key factor for the long term success of the surgery. The purpose of this study is to compare the accuracy of extramedullary and intramedullary tibial cutting guides used in indigenous and imported implants respectively, in positioning of the tibial components in megaprosthetic knee replacements. METHODS A compara...
متن کاملExtramedullary versus intramedullary tibial alignment technique in total knee arthroplasty: A meta-analysis of randomized controlled trials
The aim of this study was to establish whether the use of an extramedullary or intramedullary tibial cutting guide leads to superior mechanical leg axis and implant positioning. A meta-analysis of six randomized controlled trials including 350 knees was performed. For the mechanical axis, frontal tibial component angle and tibial slope, there were no significant differences in the mean values o...
متن کاملRadiographic results of an accelerometer-based, handheld surgical navigation system for the tibial resection in total knee arthroplasty.
In total knee arthroplasty (TKA), intramedullary and extramedullary tibial alignment guides are not proven to be highly accurate in obtaining alignment perpendicular to the mechanical axis in the coronal plane. The objective of this study was to determine the accuracy of an accelerometer-based, handheld surgical navigation system in obtaining a postoperative tibial component alignment within 2°...
متن کاملAlignment of the tibial component in total knee arthroplasty procedures using an intramedullary or extramedullary guide: double-blind randomized prospective study☆
OBJECTIVES To evaluate the results obtained through using an intramedullary or extramedullary guide for sectioning the tibia in total knee arthroplasty procedures, with a view to identifying the accuracy of these guides and whether one might be superior to the other. METHODS This was a randomized double-blind prospective study on 41 total knee arthroplasty procedures performed between August ...
متن کامل