Role of three-dimensional echocardiography in breast cancer: comparison with two-dimensional echocardiography, multiple-gated acquisition scans, and cardiac magnetic resonance imaging.

نویسندگان

  • Jonathan Walker
  • Navdeep Bhullar
  • Nazanin Fallah-Rad
  • Matthew Lytwyn
  • Mehrdad Golian
  • Tielan Fang
  • Arthur R Summers
  • Pawan K Singal
  • Ivan Barac
  • Iain D Kirkpatrick
  • Davinder S Jassal
چکیده

PURPOSE In patients with breast cancer, the administration of doxorubicin and trastuzumab is associated with an increased risk of cardiotoxicity. Although multiple-gated acquisition (MUGA) scans and two-dimensional transthoracic echocardiography (TTE) are conventional methods for baseline and serial assessment of left ventricular ejection fraction (LVEF) in these patients, little is known about the use of real-time three-dimensional TTE (RT3D TTE) in this clinical setting. The aim of this study was to assess the accuracy of MUGA, 2D TTE, and RT3D TTE for determining LVEF in comparison to cardiac magnetic resonance imaging (CMR). METHODS Between 2007 and 2009 inclusive, 50 female patients with human epidermal growth factor receptor 2-positive breast cancer received adjuvant trastuzumab after doxorubicin. Serial MUGA, 2D TTE, RT3D TTE, and CMR were performed at baseline, 6, and 12 months after the initiation of trastuzumab. RESULTS A comparison of left ventricular end diastolic volume (LVEDV) demonstrated a modest correlation between 2D TTE and CMR (r = 0.64 at baseline; r = 0.69 at 12 months, respectively). A comparison of LVEDV between RT3D TTE and CMR demonstrated a stronger correlation (r = 0.87 at baseline; r = 0.95 at 12 months, respectively). Although 2D TTE demonstrated a weak correlation with CMR for LVEF assessment (r = 0.31 at baseline, r = 0.42 at 12 months, respectively), both RT3D TTE and MUGA showed a strong correlation when compared with CMR (r = 0.91 at baseline; r = 0.90 at 12 months, respectively). CONCLUSION As compared with conventional MUGA, RT3D TTE is a feasible, accurate, and reproducible alternate imaging modality for the serial monitoring of LVEF in patients with breast cancer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation

BACKGROUND Three dimensional echocardiography (3DE) approaches the accuracy of cardiac magnetic resonance in measuring left ventricular (LV) volumes and ejection fraction (EF). The multibeat modality in comparison to single-beat (SB) requires breath-hold technique and regular heart rhythm which could limit the use of this technique in patients with atrial fibrillation (AF) due to stitching arti...

متن کامل

Analysis of left ventricular volumes and function: a multicenter comparison of cardiac magnetic resonance imaging, cine ventriculography, and unenhanced and contrast-enhanced two-dimensional and three-dimensional echocardiography.

BACKGROUND Contrast echocardiography improves accuracy and reduces interreader variability on left ventricular (LV) functional analyses in the setting of two-dimensional (2D) echocardiography. The need for contrast imaging using three-dimensional (3D) echocardiography is less defined. The aim of this multicenter study was to define the accuracy and interreader agreement of unenhanced and contra...

متن کامل

Accuracy of cardiac CT, radionucleotide and invasive ventriculography, two- and three-dimensional echocardiography, and SPECT for left and right ventricular ejection fraction compared with cardiac MRI: a meta-analysis.

AIMS Left ventricular ejection fraction (LVEF) and right ventricular ejection fraction (RVEF) are important tools in clinical decision-making. We hypothesized that two-dimensional echocardiography (2DE), three-dimensional echocardiography (3DE), radionucleotide ventriculography (RNV), cardiac computed tomography (CT), gated single-photon emission CT (SPECT), and invasive cardiac cine ventriculo...

متن کامل

Three-Dimensional Echocardiography

This brief overview relates to the recent introduction of real-time three-dimensional echocardiographic imaging techniques, which has revolutionized echocardiography, as images are obtained in just one beat. A great potential lies ahead as clinical applications are multiple. T H R E E D I M E N S I O N A L E C H O C A R D I O G R A P H Y In the past, routine clinical use of three-dimensional ec...

متن کامل

Evaluation of tissue doppler echocardiography and T2* magnetic resonance imaging in iron load of patients with thalassemia major

Background: Iron-mediated cardiomyopathy is the main complication of thalassemia major (TM) patients. Therefore, there is an important clinical need in the early diagnosis and risk stratification of patients. The aim of this study was to evaluate the efficacy of tissue doppler imaging (TDI) to study cardiac iron overload in patients with TM using T2* magnetic resonance (MR) as the gold-standard...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical oncology : official journal of the American Society of Clinical Oncology

دوره 28 21  شماره 

صفحات  -

تاریخ انتشار 2010