A Temperature-Stable Cryo-System for High-Temperature Superconducting MR In-Vivo Imaging

نویسندگان

  • In-Tsang Lin
  • Hong-Chang Yang
  • Jyh-Horng Chen
چکیده

To perform a rat experiment using a high-temperature superconducting (HTS) surface resonator, a cryostat is essential to maintain the rat's temperature. In this work, a compact temperature-stable HTS cryo-system, keeping animal rectal temperature at 37.4°C for more than 3 hours, was successfully developed. With this HTS cryo-system, a 40-mm-diameter Bi2Sr2Ca2Cu3Ox (Bi-2223) surface resonator at 77 K was demonstrated in a 3-Tesla MRI system. The proton resonant frequency (PRF) method was employed to monitor the rat's temperature. Moreover, the capacity of MR thermometry in the HTS experiments was evaluated by correlating with data from independent fiber-optic sensor temperature measurements. The PRF thermal coefficient was derived as 0.03 rad/°C and the temperature-monitoring architecture can be implemented to upgrade the quality and safety in HTS experiments. The signal-to-noise ratio (SNR) of the HTS surface resonator at 77 K was higher than that of a professionally made copper surface resonator at 300 K, which has the same geometry, by a 3.79-fold SNR gain. Furthermore, the temperature-stable HTS cryo-system we developed can obtain stable SNR gain in every scan. A temperature-stable HTS cryo-system with an external air-blowing circulation system is demonstrated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In Vivo SNR Gains for MR Micro Imaging with Cryo-cooled Copper Coils

Introduction It has recently been demonstrated that substantial SNR enhancements (3.7 times) can be achieved for in vivo MR micro imaging of small animals at 2 T field strength with superconducting RF coils, cooled to 30 K [1]. However, significant SNR gains are expected even with conventional copper coils, cooled with liquid nitrogen (77 K). The latter have several advantages in terms of simpl...

متن کامل

A magnetic resonance (MR) microscopy system using a microfluidically cryo-cooled planar coil.

We present the development of a microfluidically cryo-cooled planar coil for magnetic resonance (MR) microscopy. Cryogenically cooling radiofrequency (RF) coils for magnetic resonance imaging (MRI) can improve the signal to noise ratio (SNR) of the experiment. Conventional cryostats typically use a vacuum gap to keep samples to be imaged, especially biological samples, at or near room temperatu...

متن کامل

Evaluation of High Temperature Superconducting (HTS) Coil Performance Gain for 3T Small Animal MR Imaging

Introduction It has been widely reported that substantial signal to noise ratio (SNR) gain can be achieved through the use of the high-temperature superconducting (HTS) surface coil. Due to its complex and expensive design and construction, computational simulation is an essential design tool [1]. However estimating the likely performance gain of the HTS coil where accurate modelling of importa...

متن کامل

A Cryo-cooling Microfluidic Channel Device for Magnetic Resonance (mr) Microscopy System

ABSTRACT The development of a cryo-cooling microfluidic device for reducing the resistive noise of a magnetic resonance (MR) microcoil to improve its signal-to-noise ratio (SNR) in MR microscopy applications is presented. The radiofrequency (RF) spiral coil was cryo-cooled to liquid nitrogen temperature (-196oC) by the integrated microfluidic channels carrying liquid nitrogen for decreasing the...

متن کامل

Optimal SQUID based non-destructive test for detecting sub-surface defects with the help of advanced SQUID superconducting sensors and an experimental approach for optimal production method of these sensors from the YBCO superconductor materials

The conventional eddy current method for non-destructive inspection of welding joints has limitations that can examine defects to a certain depth below the surface of the sample and is not suitable for determining deep defects. This limitation can be overcome using the SQUID superconducting sensors. The nonstoichiometric composition of YBCO due to its superconducting temperature and desired cri...

متن کامل