Evaluation of transport ventilators at mild simulated altitude: a bench study in a hypobaric chamber.

نویسندگان

  • Salah Boussen
  • Mathieu Coulange
  • Marc Fournier
  • Marc Gainnier
  • Pierre Michelet
  • Christophe Micoli
  • Lionel Negrel
چکیده

BACKGROUND Previous studies on ventilators used for air transport showed significant effects of altitude, in particular with regard to accuracy of the tidal volume (VT) and breathing frequency. The aim of the study was to evaluate transport ventilators under hypobaric conditions. METHODS We conducted a bench study of 6 transport ventilators in a Comex hypobaric chamber to simulate mild altitude (1,500 m [4,920 feet] and 2,500 m [8,200 feet]). The ventilators were connected to a test lung to evaluate their accuracy: (1) to deliver a set VT under normal resistance and compliance conditions at F(IO2) = 0.6 and 1, (2) to establish a set PEEP (0, 5, 10, and 15 cm H2O), and (3) to establish a set inspiratory pressure in pressure controlled mode, (4) at a F(IO2) setting, and (5) and at a frequency setting. RESULTS Four ventilators kept an average relative error in VT of < 10% without effect of altitude. The Medumat ventilator was affected by the altitude only at F(IO2) = 1. The Osiris 3 ventilator had > 40% error even at 1,500 m. We found no change in frequency as a function of altitude for any ventilators studied. No clinically important differences were found between all altitudes with the PEEP or inspiratory pressure setting. Although F(IO2) was affected by altitude, the average error did not exceed 11%, and it is unclear whether this fact is an experimental artifact. CONCLUSIONS We have shown that most of the new transport ventilators tested require no setting adjustment at moderate altitude and are as safe at altitude as at sea level under normal respiratory conditions. Older technologies still deliver more volume with altitude in volumetric mode.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The performance of Dräger Oxylog ventilators at simulated altitude.

Ventilated patients frequently require transport by air in a hypobaric environment. Previous studies have demonstrated significant changes in the performance of ventilators with changes in cabin pressure (altitude) but no studies have been published on the function of modem ventilators at altitude. This experiment set out to evaluate ventilatory parameters (tidal volume and respiratory rate) of...

متن کامل

Characteristics of a rat model of an open craniocerebral injury at simulated high altitude

To establish a rat model of an open craniocerebral injury at simulated high altitude and to examine the characteristics of this model. Rats were divided randomly into a normobaric group and a high-altitude group and their corresponding control groups. A rat model of an open craniocerebral injury was established with a nail gun shot. Simulated high-altitude conditions were established with a hyp...

متن کامل

Evaluation of the Visual Analog Score (VAS) to Assess Acute Mountain Sickness (AMS) in a Hypobaric Chamber

OBJECTIVE The visual analog score (VAS) is widely used in clinical medicine to evaluate the severity of subjective symptoms. There is substantial literature on the application of the VAS in medicine, especially in measuring pain, nausea, fatigue, and sleep quality. Hypobaric chambers are utilized to test and exercise the anaerobic endurance of athletes. To this end, we evaluated the degree of A...

متن کامل

Effect of Hypobaric Hypoxia on Ascites Resistant and Susceptible Lines and Their Reciprocal F1 Crosses. 1. Pro- Duction Parameters and Ascites Mortality. Effect of Hypobaric Hypoxia on Ascites Resistant and Susceptible Lines and Their Reciprocal F1 Crosses. 2. Gut

s of papers 23 with ascites syndrome, reciprocal F1 crosses of the RES and SUS lines were produced. One objective of this multidisciplinary trial was to determine the effects of hypobaric hypoxia on gut development in the pure-line RES, pure-line SUS, and the reciprocal F1 crosses (RS, SR). Four hundred and eighty vaccinated, pedigreed broiler chickens (40 groups of 12 birds) were randomly assi...

متن کامل

Effect of Acute Exposure to Moderate Altitude on Muscle Power: Hypobaric Hypoxia vs. Normobaric Hypoxia

When ascending to a higher altitude, changes in air density and oxygen levels affect the way in which explosive actions are executed. This study was designed to compare the effects of acute exposure to real or simulated moderate hypoxia on the dynamics of the force-velocity relationship observed in bench press exercise. Twenty-eight combat sports athletes were assigned to two groups and assesse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 59 8  شماره 

صفحات  -

تاریخ انتشار 2014