Targeted box and blocks test: Normative data and comparison to standard tests

نویسندگان

  • Kimberly Kontson
  • Ian Marcus
  • Barbara Myklebust
  • Eugene Civillico
چکیده

BACKGROUND The Box and Block Test (BBT) is a functional outcome measure that is commonly used across multiple clinical populations due to its benefits of ease and speed of implementation; reliable, objective measurement; and repetition of motion. In this study, we introduce a novel outcome measure called the targeted BBT that allows for the study of initiation, grasping, and transport of objects, and also of object release. These modifications to the existing test may increase the ecological validity of the measure while still retaining the previously stated benefits of the standard BBT. METHODS 19 able-bodied subjects performed the targeted BBT and two other standard tests. Using an integrated movement analysis framework based on motion capture and ground force data, quantitative information about how subjects completed these tests were captured. Kinematic parameters at the wrist, elbow, shoulder, thorax, and head, as well as measures of postural control, were calculated and statistically compared across the three tests. RESULTS In general, the targeted BBT required significantly higher RoM at the elbow, shoulder, thorax and head when compared to standard tests. Peak angles at these joints were also higher during performance of the targeted BBT. Peak angles and RoM values for the targeted BBT were close to those found in studies of movements of able-bodied individuals performing activities of daily living. CONCLUSION The targeted BBT allows analysis of repetitive movements, and may more closely model common real-world object manipulation scenarios in which a user is required to control a movement from pick-up to release.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

هنجاریابی مقیاس تجدید نظر شده حافظه وکسلر در شهر شیراز

AbstractObjectives: In order to prepare, modify and standardize the Revised Wechsler Memory Scale, a pilot study was carried out in the city of Shiraz, after which the Farsi version of the Scale was produced. This study led to assessment of reliability as well as validity, generation of the sub-scales, and formulation of a set of standardized normative scores for the Scale. Method: 205 normal s...

متن کامل

The composition of normative groups and diagnostic decision making: shooting ourselves in the foot.

PURPOSE The normative group of a norm-referenced test is intended to provide a basis for interpreting test scores. However, the composition of the normative group may facilitate or impede different types of diagnostic interpretations. This article considers who should be included in a normative sample and how this decision must be made relative to the purpose for which a test is intended. MET...

متن کامل

Normative data for modified Box and Blocks test measuring upper-limb function via motion capture.

Motion analysis is an important tool for examining upper-limb function. Based on previous work demonstrating a modified Box and Blocks (BB) test with motion capture to assess prosthetic performance, we collected data in 16 nondisabled participants to establish normative kinematics for this test. Four motions of the modified BB test were analyzed to establish kinematic data for upper-limb and tr...

متن کامل

Case report of modified Box and Blocks test with motion capture to measure prosthetic function.

This case study report demonstrates the use of motion analysis with a modification of the Box and Blocks test. The goal was to quantify observed improvements in compensatory movements and simultaneous control in a subject using different prostheses before and after targeted muscle reinnervation (TMR) surgery. This is a single case study with data collection using a body-powered prosthesis pre-T...

متن کامل

Comparison between Clinically Used Irregular Fields Shielded by Cerrobend and Standard Lead Blocks

Introduction: In radiation therapy centers across Iran, protection of normal tissues is usually accomplished by either Cerrobend or lead block shielding. In this study, the influence of these two shielding methods on central axis dose distribution of photon beam a Cobalt unit was investigated in clinical conditions. Materials and Methods: All measurements were performed for 60Co γ-ray beams an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017