Analysis of the Voltage Stresses on Transformer Windings under Different Type of Surges

نویسندگان

  • Poulomi Mitra
  • Abhinandan De
  • Abhijit Chakrabarti
چکیده

Standard high voltage lightning and switching impulse tests are performed on Extra High Voltage (EHV) transformers during manufacture to ascertain the breakdown strength of insulation used. But during their service, transformers encounter numerous voltage transients of complex and varying wave shapes which do not necessarily resemble these standard surge type voltages. This paper reports the results of investigation on the internal response of transformer windings under standard lightning impulse voltage and system originated oscillatory transient over-voltages and the results were compared. The present study should promote understanding and assessment of voltage stresses in transformer windings under various probable terminal disturbances and this knowledge may be useful in incorporating necessary changes in transformer dielectric test standards.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Internal Protection of Transformer Windings Against Transeint Surges Using ZnO Varistors

Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...

متن کامل

Internal Protection of Transformer Windings Against Transeint Surges Using ZnO Varistors

Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...

متن کامل

A Novel Transformer-Based Single-to-Three Phase Conversion Technique Using Rotating Magnetic Field Theory

This paper presents a new single to three phase converter using rotating magnetic field transformer. Conventional transformers have been used in many converters aiming at supplementary improvements and they usually have no critical effect on the conversion technique. In this paper, the conversion technique is based on a special rotating magnetic field transformer in which there are two windings...

متن کامل

Statistical Analysis of Electrical and Mechanical Breakdown Stress for Insulation Performance in High Voltage Power Transformer

Original scientific paper In electrical power system, variety of solid, liquid and gaseous materials are used for insulation target to protect the incipient failure inside the high voltage power transformers. The insulation is practically ended when the insulation system has become fragile enough to flourish cracks under the electrical and mechanical stresses to which it is subjected. The elect...

متن کامل

Characterization of Power Transformer Electromagnetic Forces Affected by Winding Faults

Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...