A Method for Extracting Partial Discharge Signals in Transformer Winding with Wavelet Analysis
نویسندگان
چکیده
In this paper a method for extracting Partial Discharge (PD) signals is introduced, which is implemented for evaluating electrical measured partial discharges on a 66 kV / 25 MVA fully interleaved winding of a power transformer. Applying wavelet transform to a signal produces a wavelet detail coefficient distribution throughout the time-scale, which depends on the mother wavelet chosen. This method is based on the capability of the chosen mother wavelet for generating coefficients with maximum values. The paper demonstrates that the wavelet based de-noising method proposed in the paper can be employed in extracting the PD pulses from the measured signal successfully to provide enhanced information and further infer the original site of the PD pulse through capacitive ratio method. In fact, the basic idea of this method is described and applications to partial discharge studies are explored. Key-Words: Partial Discharge, Transformer, Transformer Winding, PD Location, Wavelet Transform, Signal Denoising, Signal Processing
منابع مشابه
Investigation of Partial Discharge Propagation and Location in Multiple-α and Single- Α Transformer Windings Using Optimized Wavelet Analysis
Partial discharges (PD) are recognized as the main cause of the inner insulation deterioration process in power transformers. Therefore, the optimum inner insulation design is one of the challenges a transformer designer is faced with. Transformer strength, especially during transient conditions, is a criterion for transformer insulation designers. This challenge has made designers initiate and...
متن کاملEvaluating the Improvement of Partial Discharge Localization Accuracy Using Frequency Response Assurance Criterion
Partial Discharge (PD) is the most important source of insulation degradation in power transformers. In order to prevent catastrophic failures in transformers, PDs need to be located as soon as possible so that maintenance measures can be taken in time. Due to the structural complexity of windings, locating the PD source inside a transformer winding is not a simple task. In this paper, the effi...
متن کاملOn-line Partial Discharge Monitoring System and Data Processing Using WTST-NST Filter for High Voltage Power Cable
Defects inside insulation of HV XLPE cable accessories can lead to partial discharge (PD) activity. When PD activity happens, leakage current may flow through the grounded line. To acquire the PD current signal, one practicable and effective method is placing a high frequency current transformer (HFCT) winding the grounded line. In order to measure the insulation degradation, a partial discharg...
متن کاملمدلسازی سیم پیچ ترانسفورماتورهای قدرت با استفاده از مدل خط انتقال چند سیمه بمنظور مکانیابی تخلیه جزئی
In this paper Multi conductor transmission line model (MTLM) was used for partial discharge (PD) localization in power transformers’ windings. The parameters of the model were computed considering practical issues of power transformer design. To decrease computational complexity of the model, two methods for calculation of model parameters were studied and the most suitable method was cho...
متن کاملPartial Discharge Location within a Transformer Winding Using Principal Component Analysis
Partial discharge (PD) may occur in a transformer winding due to ageing processes, operational over stressing or defects introduced during manufacture. The presence of PD does not necessarily indicate imminent failure of the transformer but it will lead to serious degradation and ageing mechanisms which can be considered as a precursor of transformer failure. A necessary step is required in ord...
متن کامل