Programmable valve shunts: are they really better?
نویسندگان
چکیده
Programmable valve shunts allows selection of opening pressure of shunt valve. In the presented article, a unique complication pertaining to programmable shunts has been discussed. A 5-year-old boy who had tectal plate low grade glioma with obstructive hydrocephalus was managed with Codman programmable ventriculoperitoneal shunt. There was a spontaneous change in the opening pressure of the shunt valve leading to shunt malfunction. Routinely used household appliances produce a magnetic field strong enough to cause change in the setting of shunt valve pressure and may lead to valve malfunction. Other causes of programmable valve malfunction also discussed.
منابع مشابه
Programmable CSF shunt valves: radiographic identification and interpretation.
The programmable CSF shunt valve has become an important tool in hydrocephalus treatment, particularly in the NPH population and in pediatric patients with complex hydrocephalus. The purpose of this study is to provide a single reference for the identification of programmable shunt valves and the interpretation of programmable shunt valve settings. Four major manufacturers of programmable shunt...
متن کاملSafety profile of long-term intraventricular access devices in pediatric patients receiving radioimmunotherapy for central nervous system malignancies.
BACKGROUND The use of Ommaya catheters or ventriculoperitoneal shunts with programmable valves (pVP-shunts) for intraventricular drug administration is increasingly more common. PROCEDURE We reviewed the safety and complication rate associated with ventricular access devices in patients receiving compartmental intraventricular radioimmunotherapy (cRIT). RESULTS One hundred fifty one patient...
متن کاملSecuring Cranial Horizontal-Vertical Valve in Proper Orientation for Use in Ventriculoperitoneal Shunting: Technical Note
Introduction: There are several options for cerebrospinal fluid diversion in patients with normal pressure hydrocephalus. Fixed and programmable valves, with or without anti-siphon devices, have been used for ventriculoperitoneal shunts and horizontal-vertical valves for lumboperitoneal shunts. Recently, a horizontal-vertical valve was developed for ventriculoperitoneal shunts and has been demo...
متن کاملImpact of Magnetic Field on Pressures of Programmable Cerebrospinal Fluid Shunts: An Experimental Study.
AIM To investigate whether programmable cerebrospinal fluid (CSF) shunts are influenced by exposure to the magnetic field and to compare the effects of magnetic field in 4 different brands of programmable CSF shunts. MATERIAL AND METHODS This experimental study was performed in the laboratory using a novel design of magnetic field. Four types of programmable CSF shunts (Miethke®, Medtronic®, ...
متن کاملImproved outcome in shunted iNPH with a combination of a Codman Hakim programmable valve and an Aesculap-Miethke ShuntAssistant.
INTRODUCTION Low pressure valves with ventriculoperitoneal shunts have been proven to lead to good outcomes in the treatment of idiopathic normal pressure hydrocephalus. However, overdrainage complications are often seen with low opening pressures. Efforts have been made to obtain good outcomes without overdrainage complications by decreasing the hydrostatic pressure component using special val...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Turkish neurosurgery
دوره 22 2 شماره
صفحات -
تاریخ انتشار 2012