GraphGas: Optimizing Outlet of Microcolumns for Gas Chromatography

نویسندگان

  • Kaitlin Howell
  • Ulrike Lehmann
  • Guillermo Villanueva
  • Alan Grisel
چکیده

This master thesis focused on optimizing the outlet geometry of microcolumn chips and how the chips are assembled in a miniaturized gas analysis system based on the principles of gas chromatography. The theory and literature of gas chromatography at microscales was studied and consequently several outlet designs were simulated with COMSOL Multiphysics®. Their theoretical velocity profiles were calculated at multiple positions in reference to a geometry acting as an gas sensor within the simulation models.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Vacuum on the Performance of the Flame Ionization DetectorUsed for Vacuum-Outlet Gas Chromatography

Vacuum-outlet operation of short fused-silica open tubular columns for gas chromatography provides benefits to analysis speed by increasing the optimum velocity while minimizing the loss in resolution. Vacuum-outlet operation of a column with a gas chromatographic detector necessitates that the detector also be under vacuum. Simple modifications were made to a gas chromatograph]flame Ž . ioniza...

متن کامل

Analysis of biomolecular interactions using affinity microcolumns: a review.

Affinity chromatography has become an important tool for characterizing biomolecular interactions. The use of affinity microcolumns, which contain immobilized binding agents and have volumes in the mid-to-low microliter range, has received particular attention in recent years. Potential advantages of affinity microcolumns include the many analysis and detection formats that can be used with the...

متن کامل

High-temperature separations on a polymer-coated fibrous stationary phase in microcolumn liquid chromatography.

Novel polymer-coated fiber-packed microcolumns in liquid chromatography (LC) have been developed. Typical polymeric materials, such as polydimethylsiloxane and polyethyleneglycol, which are conventional stationary phases of capillary columns in gas chromatography (GC), have been employed as coating materials onto the surface of fine filaments. Packed longitudinally with a bundle of polymer-coat...

متن کامل

Selectivity tuning in chiral dual column gas chromatography.

The enantioselective tuning of two columns coupled in series is investigated in chiral high-resolution gas chromatography. Two columns with opposite enantioselectivities (Chirasil-L-Val and Chirasil-D-Val) are coupled in series via a T connector, and the relative retention of enantiomers chromatographed on the system is changed by varying the individual carrier gas flow rates in the coupled col...

متن کامل

Analysis of drug-protein binding by ultrafast affinity chromatography using immobilized human serum albumin.

Human serum albumin (HSA) was explored for use as a stationary phase and ligand in affinity microcolumns for the ultrafast extraction of free drug fractions and the use of this information for the analysis of drug-protein binding. Warfarin, imipramine, and ibuprofen were used as model analytes in this study. It was found that greater than 95% extraction of all these drugs could be achieved in a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015