The long-term cost-effectiveness of cardiac resynchronization therapy with or without an implantable cardioverter-defibrillator.

نویسندگان

  • Guiqing Yao
  • Nick Freemantle
  • Melanie J Calvert
  • Stirling Bryan
  • Jean-Claude Daubert
  • John G F Cleland
چکیده

AIMS Cardiac resynchronization therapy (CRT-P) is an effective treatment for patients with heart failure and cardiac dyssynchrony with moderate or severe symptoms despite pharmacological therapy. The addition of an implantable cardioverter-defibrillator (ICD) function may further reduce the risk of sudden death. We assessed the cost-effectiveness of CRT-P compared with medical therapy (MT) alone, and the cost-effectiveness of CRT-ICD + MT compared with CRT-P + MT, on incremental cost per quality adjusted life year (QALY) and life year using data from two landmark clinical trials. METHODS AND RESULTS A Markov model with Monte Carlo simulation to assess costs, life years, and QALYs associated with CRT (+/- ICD) and MT in patients with heart failure and cardiac dyssynchrony, on the basis of a UK healthcare perspective was constructed. NYHA class distribution and transitions, associated health utilities, rates and cause of hospitalization and death were estimated from individual patient data from the CArdiac REsychronization in Heart Failure (CARE-HF trial). The estimated additional benefit on survival of an ICD was based on results from COMPANION. The base case analysis used 10 000 individual life-time simulations assuming a battery life of 6 years for CRT-P and 7 years for CRT-ICD. From a life-time perspective in a 65-year-old patient, the incremental cost-effectiveness of CRT-P compared with MT is 7538 euros (95% CI 5325-11,784 euros) per QALY gained and 7011euros (95% CI 5346-10,003 euros) per life year gained. The incremental cost-effectiveness of CRT-ICD compared with CRT-P is 47,909 euros (95% CI 35,703-79,438 euros) per QALY gained, and 35,864 euros (95% CI 26,709-56,353 euros) per life year gained. CONCLUSION Long-term treatment with CRT-P appears cost-effective compared with MT alone. From a life-time perspective, assuming a reasonable life expectancy when receiving effective treatment for heart failure, CRT-ICD may also be considered cost-effective when compared with CRT-P + MT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Sex Differences in Long-Term Outcomes With Cardiac Resynchronization Therapy in Mild Heart Failure Patients With Left Bundle Branch Block

BACKGROUND Previous studies have shown conflicting results regarding the benefit of cardiac resynchronization therapy (CRT) by sex and QRS duration. METHODS AND RESULTS In the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT), we evaluated long-term clinical outcome of heart failure (HF) or death, death, and HF alone by sex and QRS durat...

متن کامل

Primary prevention of sudden cardiac death using implantable cardioverter defibrillators.

Despite substantial advances in prevention and treatment of cardiovascular diseases, sudden cardiac death (SCD) remains a leading cause of death in industrialized countries. Implantable cardioverter defibrillator (ICD) has been demonstrated to be an attractive option for primary prevention of SCD in high-risk patients. This review discusses the progress in the risk stratification for selecting ...

متن کامل

Incidence and Costs Related to Lead Damage Occurring Within the First Year After a Cardiac Implantable Electronic Device Replacement Procedure.

BACKGROUND Inadvertent damage to leads for transvenous pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy defibrillators is an important complication associated with generator-replacement procedures. We sought to estimate the incidence and costs associated with transvenous lead damage following cardiac implantable electronic device replacement. METHODS ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 28 1  شماره 

صفحات  -

تاریخ انتشار 2007