Qualitative Evaluation of Digital Hand X-rays Is Not a Reliable Method to Assess Bone Mineral Density.
نویسندگان
چکیده
BACKGROUND The gold standard for evaluating bone mineral density is dual energy x-ray absorptiometry (DEXA). Prior studies have shown poor reliability using analog wrist X-rays in diagnosing osteoporosis. Our goal was to investigate if there was improved diagnostic value to visual assessment of digital hand X-rays in osteoporosis screening. We hypothesized that similar to analog counterparts, digital hand X-rays have poor correlation and reliability in determining bone mineral density (BMD) relative to DEXA. METHODS We prospectively evaluated female patients older than 65 years who presented to our hand clinic with digital hand and wrist X-rays as part of their evaluation over six months. Patients who had a fracture and were without DEXA scans within the past two years were excluded. Five fellowship-trained hand surgeons, blinded to DEXA T-scores, evaluated the x-rays over two assessments separated by four weeks and classified them as osteoporotic, osteopenic, or normal BMD. Accuracy relative to DEXA T-score, interobserver and intraobserver rates were calculated. RESULTS Thirty four patients met the inclusion criteria and a total of 340 x-rays reviews were performed. The assessments were correct in 169 cases (49%) as compared to the DEXA T-scores. A mean weighted kappa coefficient of agreement between observers was 0.29 (range 0.02-0.41) reflecting a fair agreement. The first and second assessment for all five physicians was 0.46 (range 0.19-0.78) reflecting a moderate agreement. Grouping osteoporosis and osteopenia together compared to normal, the accuracy, interobserver and intraobserver rates increased to 63%, 0.42 and 0.54 respectively. CONCLUSION Abnormally low BMD is a common occurrence in patients treated for upper extremity disorders. There is poor accuracy relative to DEXA scan and only fair agreement in diagnosing osteoporosis using visual assessments of digital x-rays.
منابع مشابه
Qualitative Evaluation of Digital Hand X-rays is Not a Reliable Method to Assess Bone Mineral Density
Object: The gold standard for evaluating bone mineral density is dual energy x-ray absorptiometry (DEXA). Prior studies have shown poor reliability using analog wrist X-rays in diagnosing osteoporosis. Our goal was to investigate if there was improved diagnostic value to visual assessment of digital hand X-rays in osteoporosis screening. We hypothesized that similar to analog counterparts, dig...
متن کاملComparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis
Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...
متن کاملMonte Carlo Modeling of Dual and Triple Photon Energy Absorptiometry Technique
Introduction: Osteoporosis is a bone disease in which there is a reduction in the amount of bone mineral content leading to an increase in the risk of bone fractures. The affected individuals not only have to go through lots of pain and suffering but this disease also results in high economic costs to the society due to a large number of fractures. A timely and accurate diagnosis of this disea...
متن کاملCorrelation of Bone Mineral Density and Fractal Analysis of the Mandibular Condyle in Women with Temporomandibular Joint Osteoarthritis: A Pilot Study
Background and Aim: Temporomandibular joint osteoarthritis (TMJOA) appears to be more common in osteoporotic patients. Fractal analysis is a mathematical method that can be used to assess trabecular bone. The aim of this study was to assess the correlation of bone mineral density (BMD) and fractal dimension (FD) of the condyles in women with TMJOA using cone-beam computed tomography (CBCT). ...
متن کاملEvaluation of bone mineral density in long-term survivors of childhood acute lymphoblastic leukemia
Background: The purpose of this study was to evaluate long-term changes in bone density profile among survivors of childhood acute lymphoblastic leukemia. Patients and Methods: This was a 5 year prospective study comprised of thirty-one survivors of childhood acute lymphoblastic leukemia with a mean age of 11.8 (4.6) years, who completed therapy at least 1 year previously (according to the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The archives of bone and joint surgery
دوره 5 1 شماره
صفحات -
تاریخ انتشار 2017