A digital subtraction radiography scheme based on automatic multiresolution registration.

نویسندگان

  • E I Zacharaki
  • G K Matsopoulos
  • P A Asvestas
  • K S Nikita
  • K Gröndahl
  • H-G Gröndahl
چکیده

OBJECTIVES To establish a digital subtraction radiography scheme for aligning clinical in vivo radiographs based on the implementations of an automatic geometric registration method and a contrast correction technique. METHODS Thirty-five pairs of in vivo dental radiographs from four clinical studies were used in this work. First, each image pair was automatically aligned by applying a multiresolution registration strategy using the affine transformation followed by the implementation of the projective transformation at full resolution. Then, a contrast correction technique was applied in order to produce subtraction radiographs and fused images for further clinical evaluation. The performance of the proposed registration method was assessed against a manual method based on the projective transformation. RESULTS The qualitative assessment of the experiments based on visual inspection has shown advantageous performance of the proposed automatic registration method against the manual method. Furthermore, the quantitative analysis showed statistical difference in terms of the root mean square (RMS) error estimated over the whole images and specific regions of interest. CONCLUSIONS The proposed automatic geometric registration method is capable of aligning radiographs acquired with or without rigorous a priori standardization. The methodology is pixel-based and does not require the application of any segmentation process prior to alignment. The employed projective transformation provides a reliable model for registering intraoral radiographs. The implemented contrast correction technique sequentially applied provides subtraction radiographs and fused images for clinical evaluation regarding the evolution of a disease or the response to a therapeutic scheme.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonrigid Image Registration in Digital Subtraction Angiography Using Multilevel B-Spline

We address the problem of motion artifact reduction in digital subtraction angiography (DSA) using image registration techniques. Most of registration algorithms proposed for application in DSA, have been designed for peripheral and cerebral angiography images in which we mainly deal with global rigid motions. These algorithms did not yield good results when applied to coronary angiography imag...

متن کامل

مقایسه دو نوع رادیوگرافی پانورامیک متداول و Digital Subtraction در تشخیص ضایعات شبیه‌‌‌‌‌‌سازی شده کندیل مندیبل

  Background and Aim: Digital subtraction Radiography (DSR) is a method of accurate assessing condylar head changes. several studies have been carried out in applying DSR in dentistry, however there is a few number of studies in efficacy of DSR method in assesment of condylar head changes, The aim of this study was to compare panoramic radiography and DSR detecting simulated lesions of the man...

متن کامل

بررسی دقت رادیوگرافی Digital Subtraction در تشخیص ضایعات دمینرالیزه دندانی در شرایط Invitro

سابقه و هدف: اکثریت پوسیدگی های دندانی، ضایعاتی با حدود نامشخص اند که برای مشاهده آنها بر روی رادیوگراف های conventional باید حدود 40 درصد فرآیند دمینرالیزاسیون صورت بگیرد. تصاویر رادیوگرافی معمول، عمق نفوذ یک ضایعه پوسیدگی را کمتر از مقدار واقعی آن نشان می دهند در حالیکه با استفاده از روش Digital subtraction radiography تشخیص تقلیل مواد معدنی به میزان 5-1 درصد در واحد حجم امکان پذیر است. هدف ا...

متن کامل

Automatic Registration Method for the Evaluation of Post Surgical Bony Mineralization

Digital subtraction is a common technique used in radiographic studies of periapical lesions and other dental disorders, for which the treatment must be evaluated over time. This paper presents a fast and reliable parallel image registration method for subtracting two digitized radiographs where an unpredicted mismatch is present. An optimal affine transformation is found using an adaptive Gene...

متن کامل

A Robust Algorithm for Automatic Registration of Intraoral Radiographs

Background Subtraction techniques enable precise quantiication of changes in dental tissue structure. Automatic subtraction of intra-oral radiographs acquired without individual adjustment aids requires a-posteriori correction of geometry and contrast diierences, i.e. registration. Methods Previous work has shown that perspective projection is a reliable model for sequential radiographs regardl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dento maxillo facial radiology

دوره 33 6  شماره 

صفحات  -

تاریخ انتشار 2004