Examination of performance of glassy carbon paste electrode modified with gold nanoparticle and xanthine oxidase for xanthine and hypoxanthine detection.
نویسندگان
چکیده
A composite electrode was prepared by modifying glassy carbon microparticles with gold nanoparticles (Au-nps) and xanthine oxidase enzyme (XOD) for xanthine (X) and hypoxanthine (Hx) detection. After the optimization of the system for X, the biosensor was characterized for X and Hx. A linearity was obtained in the concentration range between 5.00 x 10(-7) and 1.00 x 10(-5) M for X with equation of y=0.24 x + 0.712 and 5.00 x 10(-6) to 1.50 x 10(-4) M for Hx, with equation of y = 0.014 x + 0.575, respectively. Obtained results were compared to X and/or Hx biosensors including/not including Au-np in the structure. The developed system was also applied for detection of Hx in canned tuna fish sample and very promising results were obtained.
منابع مشابه
New Two-fold Amplified Electroanalytical Sensor for Determination of Xanthine in the Presences of Caffeine in Food Samples
Fast and sensitive response electrochemical sensor based on CoFe2O4 nanoparticle and 1-buthyl-3-methyl imidazolium bromide room temperature ionic liquids carbon paste electrode (CoFe2O4/NP/ILs/CPE) is fabricated for the determination of Xanthine (Xt) in the presences of Caffeine in fish and fruit samples. In the first step, CoFe2O4</su...
متن کاملAmperometric biosensor for xanthine determination based on Fe3O4 nanoparticles.
An amperometric xanthine biosensor was developed based on the immobilization of xanthine oxidase (XO) into the Fe3O4 nanoparticles modified carbon paste. Electron transfer properties of unmodified and Fe3O4 nanoparticles modified carbon paste electrodes were investigated by cyclic voltammetry and electrochemical impedance spectroscopy. Fe3O4 nanoparticles increased electroactive surface area of...
متن کاملSimultaneous determination of dopamine and uric acid using a glassy carbon paste electrode modified with copper- para red complex
A simple approach based on cyclic voltammetry (CV) was developed for the simultaneous determination of dopamine (DA) and uric acid (UA) in the presence of ascorbic acid (AA) using a modified glassy carbon paste electrode (GCPE). In the present study, analytical parameters were optimized and electrochemical performance of modified electrode was investigated. The calibration curves were obtained ...
متن کاملElectrodeposition of anionic, cationic and nonionic surfactants and gold nanoparticles onto glassy carbon electrode for catechol detection
Three surfactants were selected to modify glassy carbon electrode including sodiumdodecylbenzenesulfonate, Tween 80 and cetyltrimethylammonium bromide. The obtained nano-Au/surfactant/GCEs were characterized with scanning electron microscopy and electrochemicaltechniques. Electrochemical behavior of catechol at the nano-Au/surfactant/GCE was thoroughlyinvestigated for mo...
متن کاملSelective Electrochemical Nanosensor based on Modified Carbon Paste Electrode for Determination of NADH in the presence of Uric Acid
The electrochemical properties of a modified carbon paste electrode with the synthesized compound of 2,2'-[1,7–heptanediylbis(nitrilomethylidene)]-bis(4-hydroxyphenol) (DHBH) and graphite nanoparticle (GN) were studied by cyclic voltammetry (CV), chronoamperometry and differential pulse voltammetry (DPV) methods. The proposed electrode shows excellent electrocatalytic activity towards the oxida...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Talanta
دوره 74 3 شماره
صفحات -
تاریخ انتشار 2007