Superior accuracy of model-based radiostereometric analysis for measurement of polyethylene wear

نویسندگان

  • M. Stilling
  • S. Kold
  • S. de Raedt
  • N. T. Andersen
  • O. Rahbek
  • K. Søballe
چکیده

OBJECTIVES The accuracy and precision of two new methods of model-based radiostereometric analysis (RSA) were hypothesised to be superior to a plain radiograph method in the assessment of polyethylene (PE) wear. METHODS A phantom device was constructed to simulate three-dimensional (3D) PE wear. Images were obtained consecutively for each simulated wear position for each modality. Three commercially available packages were evaluated: model-based RSA using laser-scanned cup models (MB-RSA), model-based RSA using computer-generated elementary geometrical shape models (EGS-RSA), and PolyWare. Precision (95% repeatability limits) and accuracy (Root Mean Square Errors) for two-dimensional (2D) and 3D wear measurements were assessed. RESULTS The precision for 2D wear measures was 0.078 mm, 0.102 mm, and 0.076 mm for EGS-RSA, MB-RSA, and PolyWare, respectively. For the 3D wear measures the precision was 0.185 mm, 0.189 mm, and 0.244 mm for EGS-RSA, MB-RSA, and PolyWare respectively. Repeatability was similar for all methods within the same dimension, when compared between 2D and 3D (all p > 0.28). For the 2D RSA methods, accuracy was below 0.055 mm and at least 0.335 mm for PolyWare. For 3D measurements, accuracy was 0.1 mm, 0.2 mm, and 0.3 mm for EGS-RSA, MB-RSA and PolyWare respectively. PolyWare was less accurate compared with RSA methods (p = 0.036). No difference was observed between the RSA methods (p = 0.10). CONCLUSIONS For all methods, precision and accuracy were better in 2D, with RSA methods being superior in accuracy. Although less accurate and precise, 3D RSA defines the clinically relevant wear pattern (multidirectional). PolyWare is a good and low-cost alternative to RSA, despite being less accurate and requiring a larger sample size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of a new 2-D technique for radiographic wear measurement of cemented, highly cross-linked polyethylene acetabular cups

A new 2-D radiographic wear measurement system has been developed which enables the low wear of highly cross-linked polyethylene acetabular cups to be accurately and precisely measured from standard, pelvis radiographs. The software was validated using radiographic images of a measurement jig which could vary the cup orientation and simulate the effect of pelvic tilt/rotation. Wear was simulate...

متن کامل

The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis.

The creep and wear behaviour of highly cross-linked polyethylene and standard polyethylene liners were examined in a prospective, double-blind randomised, controlled trial using radiostereometric analysis. We randomised 54 patients to receive hip replacements with either highly cross-linked polyethylene or standard liners and determined the three-dimensional penetration of the liners over three...

متن کامل

No effect of additional screw fixation of a cementless, all-polyethylene press-fit socket on migration, wear, and clinical outcome

Background and purpose - Additional screw fixation of the all-polyethylene press-fit RM cup (Mathys) has no additional value for migration, in the first 2 years after surgery. However, the medium-term and long-term effects of screw fixation remain unclear. We therefore evaluated the influence of screw fixation on migration, wear, and clinical outcome at 6.5 years using radiostereometric analysi...

متن کامل

A Novel Method for Assessment of Polyethylene Liner Wear in Radiopaque Tantalum Acetabular Cups: Clinical Validation in Patients Enrolled in a Randomized Controlled Trial.

Conventional radiostereometric analysis (RSA) for wear is not possible in patients with tantalum cups. We propose a novel method for wear analysis in tantalum cups. Wear was assessed by gold standard RSA and the novel method in total hip arthroplasty patients enrolled in a randomized controlled trial receiving either titanium or tantalum cups (n=46). The novel method estimated the center of the...

متن کامل

Cross-linked polyethylene and bisphosphonate therapy for osteolysis in total hip arthroplasty: a case report.

A 39-year-old woman underwent bilateral total hip arthroplasty with conventional, ethylene oxide-sterilised liners when she was a subject in a radiostereometric analysis study. Within 2 years she had rapid polyethylene wear with aggressive, asymptomatic, and periprosthetic osteolysis on both sides. Oral alendronate therapy halted the progression of osteolysis over a year and revision to cross-l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2012