Changes in spherical aberration after lens refilling with a silicone oil.

نویسندگان

  • Kwok-Hoi Wong
  • Steven A Koopmans
  • Thom Terwee
  • Aart C Kooijman
چکیده

PURPOSE It may be possible to restore accommodation to presbyopic human eyes by refilling the lens capsular bag with a soft polymer. In the present study, optical changes were measured that occurred in a pig eye model after the refilling of the capsular bag. METHODS The optical power and spherical aberration in 10 isolated pig lenses were measured under different conditions. They were first determined by using a scanning laser ray-tracing technique over an effective pupil size of 6 mm. Second, the contours of the anterior and posterior lens surface were photographed, and a mathematical ray-tracing was performed by using a polynomial fit through the digitized surface contours, to determine optical power and spherical aberration. Third, the lenses were refilled with a silicone oil until their preoperative lens thickness was reached, and scanning laser ray-tracing, contour photography, and mathematical ray-tracing were repeated. Comparisons between the measurements were made to determine how the change from a gradient refractive index to a homogeneous refractive index influenced spherical aberration. The influence of the change in lens contour on spherical aberration after lens refilling was also studied. RESULTS The natural lenses had a higher lens power than the refilled lenses (49.9 +/- 1.5 D vs. 36.8 +/- 1.5 D; P < 0.001). Moreover, there was a change in sign from negative spherical aberration before lens refilling (-3.6 D) to positive spherical aberration after lens refilling (7.9 D; P < 0.001). The comparison between scanning laser ray-tracing of the natural lens and mathematical ray-tracing of the photographed surface contours of the natural lens to determine the effect of refractive index substitution (i.e., replacement of a gradient refractive index by a homogeneous refractive index) showed a significant change in spherical aberration from -3.6 +/- 2.0 to 11.0 +/- 2.1 D (P < 0.001). The change in lens contour did not result in a significant change in spherical aberration (P = 0.08) before and after lens refilling with an equal refractive index. CONCLUSIONS The lower lens power of refilled pig lenses compared to natural lenses was due to the lower refractive index of the refill material. Refilling pig lenses with the silicone oil used in this study resulted in an increase in spherical aberration. This increase was mainly caused by the change from a gradient refractive index to a homogeneous refractive index. The change in lens curvature after lens refilling did not result in an increase in spherical aberration. The influence of lens refilling on spherical aberration of human lenses must be determined in similar experiments in human eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relation between injected volume and optical parameters in refilled isolated porcine lenses.

PURPOSE This study was performed to elucidate the correlation between added lens refill material and enhanced lens power as well as the correlation between lens refilling volume and accommodative amplitude as determined by equatorial stretching of ex vivo refilled pigs' lenses. METHODS Nine porcine lenses were refilled with increasing amounts of silicone oil. After each refill step, the lens ...

متن کامل

Accommodation amplitude after lens refilling with injectable silicone by sealing the capsule with a plug in primates.

OBJECTIVE To restore accommodation in primate eyes by refilling the lens capsule with injectable silicone compounds. MATERIALS AND METHODS Eight eyes of 8 monkeys (Macaca fascicularis) were treated by the lens refilling procedure. To prevent leakage of the injected liquid silicone before it polymerized in the capsule in vivo, a silicone plug for sealing the capsular opening was developed. Aft...

متن کامل

Lenticular accommodation in relation to ametropia: the chick model.

Our goal was to determine whether experimentally induced ametropias have an effect on lenticular accommodation and spherical aberration. Form-deprivation myopia and hyperopia were induced in one eye of hatchling chicks by application of a translucent goggle and +15 D lens, respectively. After 7 days, eyes were enucleated and lenses were optically scanned prior to accommodation, during accommoda...

متن کامل

Achromatic doublet intraocular lens for full aberration correction.

A doublet intraocular lens optimized for both chromatic and monochromatic aberration correction in pseudophakic eyes is presented. Ray-tracing techniques were applied to design the lens in white light within a chromatic eye model. Combinations of two materials, already commonly used in intraocular lenses, as acrylic and silicone, were used. Iterative optimization algorithms were employed to cor...

متن کامل

Intraoperative biometry for intraocular lens (IOL) power calculation at silicone oil removal.

PURPOSE Cataract development is common following retinal detachment surgery that necessitates silicone oil injection. Intraocular lens (IOL) power calculation in the presence of silicone oil is challenging for many reasons. The authors evaluated the accuracy of intraoperative biometry during cataract surgery in silicone-filled eyes. METHODS Twelve cases of cataract in eyes filled with silicon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 48 3  شماره 

صفحات  -

تاریخ انتشار 2007