Stereotactic Arrhythmia Radioablation (STAR) of Ventricular Tachycardia: A Treatment Planning Study
نویسندگان
چکیده
PURPOSE The first stereotactic arrhythmia radioablation (STAR) of ventricular tachycardia (VT) was delivered at Stanford on a robotic radiosurgery system (CyberKnife® G4) in 2012. The results warranted further investigation of this treatment. Here we compare dosimetrically three possible treatment delivery platforms for STAR. METHODS The anatomy and target volume of the first treated patient were used for this study. A dose of 25 Gy in one fraction was prescribed to the planning target volume (PTV). Treatment plans were created on three treatment platforms: CyberKnife® G4 system with Iris collimator (Multiplan, V. 4.6)(Plan #1), CyberKnife® M6 system with InCise 2(TM) multileaf collimator (Multiplan V. 5.3)(Plan #2) and Varian TrueBeam(TM) STx with HD 120(TM) MLC and 10MV flattening filter free (FFF) beam (Eclipse planning system, V.11) (Plan #3 coplanar and #4 noncoplanar VMAT plans). The four plans were compared by prescription isodose line, plan conformity index, dose gradient, as well as dose to the nearby critical structures. To assess the delivery efficiency, planned monitor units (MU) and estimated treatment time were evaluated. RESULTS Plans #1-4 delivered 25 Gy to the PTV to the 75.0%, 83.0%, 84.3%, and 84.9% isodose lines and with conformity indices of 1.19, 1.16, 1.05, and 1.05, respectively. The dose gradients for plans #1-4 were 3.62, 3.42, 3.93, and 3.73 with the CyberKnife® MLC plan (Plan #2) the best, and the TrueBeam(TM) STx co-planar plan (Plan #3) the worst. The dose to nearby critical structures (lung, stomach, bowel, and esophagus) were all well within tolerance. The MUs for plans #1-4 were 27671, 16522, 6275, and 6004 for an estimated total-treatment-time/beam-delivery-time of 99/69, 65/35, 37/7, and 56/6 minutes, respectively, under the assumption of 30 minutes pretreatment setup time. For VMAT gated delivery, a 40% duty cycle, 2400MU/minute dose rate, and an extra 10 minutes per extra arc were assumed. CONCLUSION Clinically acceptable plans were created with all three platforms. Plans with MLC were considerably more efficient in MU. CyberKnife® M6 with InCise 2(TM) collimator provided the most conformal plan (steepest dose drop-off) with significantly reduced MU and treatment time. VMAT plans were most efficient in MU and delivery time. Fluoroscopic image guidance removes the need for additional fiducial marker placement; however, benefits may be moderated by worse dose gradient and more operator-dependent motion management by gated delivery.
منابع مشابه
Ablative Radiotherapy as a Noninvasive Alternative to Catheter Ablation for Cardiac Arrhythmias
PURPOSE OF REVIEW Stereotactic radioablation is a commonly utilized technology to noninvasively treat solid tumors with precision and efficacy. Using a robotic arm mounted delivery system, multiple low-dose ionizing radiation beams are delivered from multiple angles, concentrating ablative energy at the target tissue. Recently, this technology has been evaluated for treatment of cardiac arrhyth...
متن کاملStereotactic ablative radiotherapy for the treatment of refractory cardiac ventricular arrhythmia.
Case Report A 71-year-old man with coronary artery disease, coronary artery bypass grafting in 2000, baseline ejection fraction of 0.24, and implantation of a single chamber implanted cardioverter defibrillator (ICD) in 2009 for ventricular tachycardia (VT) presented with continuous episodes of nonsustained and sustained VT refractory to sotalol and mexiletine. Despite angioplasty and stent for...
متن کاملEllagic acid improved arrhythmias induced by CaCL2 in the rat stress model
Objective: In ventricular arrhythmias, due to their free radical scavenging action, antioxidant agents are usually used in the treatment of cardiovascular disease. Since stress is considered as risk factor for increased mortality by causing malignant arrhythmias, the study was designed to evaluate the cardioprotective effects of ellagic acid (EA) on CaCl2-induced arrhythmias in rat stress model...
متن کاملThe Effect of Opium Addiction on Cardiac Arrhythmia after Acute Myocardial Infarction
Background & Aims: This study was carried out to assess the effect of opium addiction on the incidence of different types of arrhythmias after acute myocardial infarction (AMI). Methods: The study population consisted of 200 patients with first AMI admitted within 6 hours of the onset of chest pain to the coronary care units (CCU) of two hospitals affiliated to Kerman University of Medical Scie...
متن کاملProlonged Oral Administration of Oleuropein Might Protect Heart against Aconitine-induced Arrhythmia
In this study, it was surveyed to know whether an oral single dose of oleuropein could mimic the cardiac preconditioning in rats’ hearts or whether its prolonged oral administration could protect the heart against the aconitine-induced arrhythmia in rats. Eighty male Wistar rats were divided into two series (n = 8 in each group). In the first series, all groups (except the control (Con) group) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2016