Systematic Left Ventricular Assist Device Implant Eligibility with Non-Invasive Assessment: The SIENA Protocol

نویسندگان

  • Matteo Cameli
  • Ferdinando Loiacono
  • Stefania Sparla
  • Marco Solari
  • Elisabetta Iardino
  • Giulia Elena Mandoli
  • Sonia Bernazzali
  • Massimo Maccherini
  • Sergio Mondillo
چکیده

In patients with end-stage left ventricular (LV) heart failure who receive LV assist device (LVAD) implantation, right ventricular (RV) failure represents a possible critical complication that heavily affects morbidity and mortality. Several clinical, laboratory, hemodynamic, and echocardiographic variables have been found to be associated with RV failure occurrence after surgery. Different models and risk scores have been proposed, with poor results. No accordance has ever been reached about RV pre-operative evaluation, and time has come to introduce a standardized systematic protocol for LVAD suitability assessment according to RV function. We analyzed imaging parameters associated with LVAD implantation-related RV failure, in order to identify the minimum number for pre-operative reliable prediction of post-operative RV failure. A few echocardiographic parameters have been identified as the most reliable, or promising, and reproducible tools in this field: free-wall RV longitudinal strain, RV fractional area change, RV sphericity index, and RV ejection fraction with 3D-echocardiography. We propose the Systematic LVAD Implant Eligibility with Non-invasive Assessment protocol-the SIENA protocol-as a new and simple way of pre-operative evaluation of patients candidates to LVAD implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

An alternative approach to explantation and exchange of the HeartWare left ventricular assist device.

OBJECTIVES Left ventricular assist device (LVAD) explantation and exchange is a relatively infrequent but potentially complex procedure. Patients requiring such procedures have multisystem suboptimal physiological reserve due to end-stage heart failure and are prone to complications. Less-invasive procedures are believed to facilitate postoperative recovery and early mobilization. We describe a...

متن کامل

Myocardial recovery in peri-partum cardiomyopathy after continuous flow left ventricular assist device

Left ventricular assist devices (LVADs) offer effective therapy for severe heart failure (HF) as bridge to transplantation or destination therapy. Rarely, the sustained unloading provided by the LVAD has led to cardiac reverse remodelling and recovery, permitting explantation of the device. We describe the clinical course of a patient with severe peri-partum cardiomyopathy (PPCM) rescued with a...

متن کامل

Successful bridge to recovery using two-stage HeartWare LVAD explantation approach after embolic stroke

A two-stage explantation of a left ventricular assist device (LVAD) was performed on 47 year old afro-american gentlemen with non-ischemic dilated cardiomyopathy (DCM) who was successfully bridged to recovery. After he suffered a stroke caused by a VAD thrombosis with embolisation, the VAD outflow graft was first ligated using minimally-invasive approach. Two months later, the device was explan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 25  شماره 

صفحات  -