Artifacts in Atomic Force Microscopy of Biological Samples
نویسندگان
چکیده
Atomic force microscopy (AFM) is a frequently used method applicable also to biological studies due to its capability of measuring in native environment. Sharp Si, Si3N4 or C (carbon nanotubes, diamond, diamond coated) cantilevers repeatedly touching a sample are used in this method as sensitive probes. It is possible to control the interaction between the tip and the sample in order to make less invasive measurements or, conversely, to modify the sample. However, AFM images often contain features which are not present on the sample in reality, but are a direct result of the measurements itself. Such structures or features are denoted as artifacts. The artifacts arise from various reasons. Some of them can be avoided during measurements, other ones are inherent. The artifacts shown in this chapter are divided into several categories based on the part of AFM which is responsible for them. Examples of many artifacts are presented and their reasons are explained. This chapter will be helpful for AFM users who observe strange effects, presumably related to the AFM technique, but do not know their reason. This chapter can also answer questions about the validity of imaged features as well as their accuracy.
منابع مشابه
Atomic Force Microscopy Application in Biological Research: A Review Study
Atomic force microscopy (AFM) is a three-dimensional topographic technique with a high atomic resolution to measure surface roughness. AFM is a kind of scanning probe microscope, and its near-field technique is based on the interaction between a sharp tip and the atoms of the sample surface. There are several methods and many ways to modify the tip of the AFM to investigate surface properties, ...
متن کاملTip-induced artifacts in magnetic force microscopy images
Useful sample information can be extracted from the dissipation in frequency modulation atomic force microscopy due to its correlation to important material properties. It has been recently shown that artifacts can often be observed in the dissipation channel, due to the spurious mechanical resonances of the atomic force microscope instrument when the oscillation frequency of the force sensor c...
متن کاملSensitivity Analysis of Frequency Response of Atomic Force Microscopy in Liquid Environment on Cantilever's Geometrical Parameters
In this paper, the non-linear dynamic response of rectangular atomic force microscopy in tapping mode is considered. The effect of cantilever’s geometrical parameters (e.g., cantilever length, width, thickness, tip length and the angle between the cantilever and the sample's surface in liquid environment has been studied by taking into account the interaction forces. Results indicate that the r...
متن کاملApplication of Scanning Electron and Atomic Force Mode Microscopy on inscription from Proto-Elamite period in Tappeh Sofalin
The study of cultural heritage artifacts and the research of a protection and restoration intervention create with - and are often limited to - a complete characterization of their surface. This is not only factual for museum objects, but also for archaeological artifacts, because the object as it was discovered may contain precious unknown information that could be lost by too much aggressive ...
متن کاملDevelopment of an Algorithm for Tip-related Artifacts Identification in AFM Biological Film Imaging
One major drawback identified in atomic force microscopy imaging is the dependence of the image’s precision on the shape of the probe tip. In this paper a simple algorithm is proposed to provide artifact identification signaling in-situ tip features in atomic force microscopy images. The base of the identifications lied when the angle formed between two scanned points was kept the same as the t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -