Percutaneous tricuspid valve repair using MitraClip® for the treatment of severe tricuspid valve regurgitation in a patient with congenitally corrected transposition of the great arteries
نویسندگان
چکیده
In selected patients, mitral valve repair using MitraClip® (Abbott, USA) is a relatively safe and well-tolerated treatment for significant mitral regurgitation [1–3]. We describe a 56-year-old female with congenitally corrected transposition of the great arteries (ccTGA) and dextrocardia (Fig. 1a) with recurrent episodes of heart failure caused by a combination of systemic (right) ventricular failure and tricuspid valve regurgitation (Fig. 1b). ccTGA is a rare congenital heart defect with discordance at both the atrioventricular and the ventriculoarterial level. In 20% of the patients dextrocardia exists. Moderate to severe tricuspid valve regurgitation has a clear impact on cardiac prognosis [4]. We performed a percutaneous tricuspid valve repair using
منابع مشابه
Surgical repair of both atrioventricular valves in congenitally corrected transposition of the great arteries with dextrocardia.
Patients with congenitally corrected transposition of the great arteries (CCTGA) have a morphologically right ventricle (mRV) that supports the systemic circulation. In these patients, regurgitation of the systemic tricuspid valve (TV) is one of the strongest risk factors for congestive heart failure and mRV dysfunction. Herein, we report the case of a patient with CCTGA plus dextrocardia who u...
متن کاملRight sided heart evaluation after successful mitral valve replacement.
Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...
متن کاملTransapical transcatheter aortic valve implantation followed by transfemoral transcatheter edge-to-edge repair of the tricuspid valve using the MitraClip system – a new treatment concept for an inoperable patient with significant aortic stenosis and severe tricuspid valve regurgitation
Corresponding author: Marek Kowalski MD, PhD, Cardiology Department, Schuechtermann-Klinik, Ulmenallee 5-11, 49214 Bad Rothenfelde, Germany, phone: +49 542464130023, e-mail: [email protected] Received: 3.05.2016, accepted: 11.06.2016. Transapical transcatheter aortic valve implantation followed by transfemoral transcatheter edge-to-edge repair of the tricuspid valve using the M...
متن کاملPreservation of systemic tricuspid valve function by pulmonary conduit banding in a patient with corrected transposition of the great arteries.
Systemic tricuspid valve regurgitation increases mortality and morbidity in patients with a corrected transposition of the great arteries. A 17-year old male with a physiologically corrected transposition after the closure of a ventricular septal defect and conduit placement between a morphological left ventricle and pulmonary artery presented with exertional dyspnoea. The transthoracic echocar...
متن کاملCombined arterial switch and Senning operation for congenitally corrected transposition of the great arteries: patient selection and intermediate results.
OBJECTIVE Late results after traditional methods of repair of congenitally corrected transposition of the great arteries are poor. The combined arterial switch and Senning (double switch) operation may improve outcomes by using the morphologically left ventricle and mitral valve in the systemic circulation. In this report we review patient selection and intermediate results after the double swi...
متن کامل