Resolution improvement in laser diode-based pump-probe microscopy with an annular pupil filter.

نویسندگان

  • Jun Miyazaki
  • Koshi Kawasumi
  • Takayoshi Kobayashi
چکیده

We experimentally demonstrate the use of annular beams to improve lateral resolution in laser-diode-based pump-probe microscopy. We found that the width of the point-spreading function in the case of the annular pump-probe beams is 162 nm, which is 30% smaller than that of the circular beams (232 nm). Furthermore, side lobes were efficiently suppressed at the focal plane since the pump-probe signal is proportional to the product of the two beam intensities. This scheme is demonstrated for the photothermal signal of nonfluorescent gold nanoparticles and the stimulated emission signal of fluorescence beads.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Annular pupil filter under shot-noise condition for linear and non linear microscopy.

The imaging performances of multiphoton excitation and confocal laser scanning microscopy are herby considered: in typical experimental imaging conditions, a small finite amount of photon reaches the detector giving shot-noise fluctuations which affects the signal acquired. A significant detriment in the high frequencies transmission capability is obtained. In order to partially recover the hig...

متن کامل

Implementation of intensity-modulated laser diodes in time-resolved, pump-probe fluorescence microscopy.

We present the implementation of intensity-modulated laser diodes for applications in frequency-domain pump-probe fluorescence microscopy. Our technique, which is based on the stimulated-emission approach, uses two sinusoidally modulated laser diodes. One laser (635 nm) excites the chromophores under study, and the other laser (680 nm) is responsible for inducing stimulated emission from excite...

متن کامل

Tuning extension of a Difference-Frequency generation up to 100 nm using V-shaped external-cavity for the pump laser

In this research, tunability of a commercial diode laser has extended to about more than ± 11 nm using a V-shaped external-cavity fabricated around the laser. Although under normal condition it can be tuned up to about ± 4 nm just by changing its temperature and injection current. Such modified diode laser has then used in a difference-frequency generation (DFG) experimental setup as pump sourc...

متن کامل

Scanning impedance microscopy (SIM): A novel approach for AC transport imaging

Scanning Impedance Microscopy (SIM) is one of the novel scanning probe microscopy (SPM) techniques, which has been developed to taking image from sample surface, providing quantitative information with high lateral resolution on the interface capacitance, and investigating the local capacitance–voltage (C–V) behavior of the interface and AC transport properties. The SIM is an ordinary AFM equip...

متن کامل

Scanning impedance microscopy (SIM): A novel approach for AC transport imaging

Scanning Impedance Microscopy (SIM) is one of the novel scanning probe microscopy (SPM) techniques, which has been developed to taking image from sample surface, providing quantitative information with high lateral resolution on the interface capacitance, and investigating the local capacitance–voltage (C–V) behavior of the interface and AC transport properties. The SIM is an ordinary AFM equip...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics letters

دوره 39 14  شماره 

صفحات  -

تاریخ انتشار 2014