In vivo and in vitro biofilm formation on two different titanium implant surfaces.
نویسندگان
چکیده
OBJECTIVES The aim of the present in vitro and human in vivo study was twofold: first, to evaluate the initial biofilm formation on different titanium implant surfaces by means of two highly sensitive fluorescent techniques and, second, to correlate these findings to different surface properties. MATERIALS AND METHODS In vivo biofilm formation was induced on purely machined (Pt) and on sand-blasted and acid-etched titanium (Prom) specimens, which were mounted buccally on individual splints and worn by six study participants for 12 h. In vitro bacterial adhesion was also investigated after incubation with Streptococcus sanguinis suspension (37 degrees C, 2 h). Adherent bacteria were quantified by the following fluorescence techniques: Resazurin staining in combination with an automated fluorescence reader or live/dead cell labeling and fluorescence microscopy. Surface roughness (R(a)) was determined with a perthometer, and surface free energy (SFE) was measured with a goniometer. RESULTS Prom showed a significantly higher median R(a) (0.95 microm) and a significantly lower median SFE (18.3 mJ/m(2)) than Pt (R(a)=0.15 microm; SFE=39.6 mJ/m(2)). The in vitro and in vivo tests showed a significantly higher bacterial adhesion to Prom than to Pt, and the initial biofilm formation on Pt corresponded to the circular surface modifications on the machined substratum. Both observations may be attributed to the predominant influence of surface roughness on bacterial adhesion. No significant differences in the percentage of dead cells among all adhering bacteria were found between Prom (23.7%) and Pt (29.1%). Ectopic solitary epithelial cells from the oral mucosa - strongly adhering to the substratum - were found on each Prom specimen, but not on any of the Pt surfaces. CONCLUSIONS Initial bacterial adhesion to differently textured titanium surfaces is primarily influenced by R(a), whereas the influence of SFE seems to be of only minor importance. Therefore, the micro-structured parts of an implant that are exposed to the oral cavity should be highly polished to prevent plaque accumulation. Both tested fluorometric techniques proved to be highly sensitive and reproducible in the quantification of biofilm formation on titanium implant surfaces.
منابع مشابه
Oral Streptococci Biofilm Formation on Different Implant Surface Topographies
The establishment of the subgingival microbiota is dependent on successive colonization of the implant surface by bacterial species. Different implant surface topographies could influence the bacterial adsorption and therefore jeopardize the implant survival. This study evaluated the biofilm formation capacity of five oral streptococci species on two titanium surface topographies. In vitro biof...
متن کاملPolyspecies biofilm formation on implant surfaces with different surface characteristics
OBJECTIVE To investigate the microbial adherence and colonization of a polyspecies biofilm on 7 differently processed titanium surfaces. MATERIAL AND METHODS Six-species biofilms were formed anaerobically on 5-mm-diameter sterilized, saliva-preconditioned titanium discs. Material surfaces used were either machined, stained, acid-etched or sandblasted/acid-etched (SLA). Samples of the latter t...
متن کاملSoft tissue integration versus early biofilm formation on different dental implant materials.
OBJECTIVE Dental implants anchor in bone through a tight fit and osseo-integratable properties of the implant surfaces, while a protective soft tissue seal around the implants neck is needed to prevent bacterial destruction of the bone-implant interface. This tissue seal needs to form in the unsterile, oral environment. We aim to identify surface properties of dental implant materials (titanium...
متن کاملAntibacterial coatings on titanium surfaces: a comparison study between in vitro single-species and multispecies biofilm.
Dental plaque is a biofilm that causes dental caries, gingivitis, and periodontitis. Most of the studies in antibacterial coatings have been conducted by in vitro single-species biofilm formation, but oral biofilm involves more than 700 different bacterial species that are able to interact. Therefore, new studies are focused on in vitro multispecies biofilm models that mimic in vivo biofilms. T...
متن کاملSilver-Containing Hydroxyapatite Coating Reduces Biofilm Formation by Methicillin-Resistant Staphylococcus aureus In Vitro and In Vivo
Biofilm-producing bacteria are the principal causes of infections associated with orthopaedic implants. We previously reported that silver-containing hydroxyapatite (Ag-HA) coatings exhibit high antibacterial activity against methicillin-resistant Staphylococcus aureus (MRSA). In the present study, we evaluated the effects of Ag-HA coating of implant surfaces on biofilm formation. Titanium disk...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical oral implants research
دوره 21 2 شماره
صفحات -
تاریخ انتشار 2010