Ozone measurements in South Carolina using passive samplers.

نویسندگان

  • Anna C Franklin
  • Lynn G Salmon
  • Jack M Wolfson
  • Christos S Christoforou
چکیده

Passive samplers with two different collection substrates were used to obtain an average ozone concentration for 1 month during the summer of 2002 for each South Carolina county. One sampler contained a filter coated with indigo carmine, whose color fades when exposed to ozone. The fading was measured by reflectance spectroscopy. The other sampler contained filters that were coated with nitrite, which is oxidized to nitrate when exposed to ozone. The nitrate was measured by ion chromatography. Calibration curves were developed for the two methods by comparing color fading from indigo carmine and nitrate ion concentration from the nitrite filter with ambient ozone concentration measured by a co-located reference continuous UV ozone analyzer. These curves were used to calculate integrated ozone concentrations for samplers distributed across South Carolina. Using the indigo carmine method, the average ozone concentrations ranged from 21 to 64 ppb (average = 46 +/- 7.9 ppb, n = 58) across the 46 counties in the state during one summer month of 2002. Concentrations for the same time period from the nitrite-coated filters ranged from 23 to 62 ppb (average = 41 +/- 8.1 ppb, n = 58). Also for the same time period, the 23 continuous UV photometric ozone monitors operated by the South Carolina Department of Health and Environmental Control at sites within 10 miles of some of the passive monitors showed ozone concentrations ranging from 28 to 50 ppb (average = 39 +/- 6.3 ppb, n = 22).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Final Report Improving Model Estimates of Smoke Contributions to Regional Haze Using Low-cost Sampler Systems

Robust low-cost sampler systems allowing for monitoring of air pollutants important for air quality resulting from forest fires and urban/agricultural activities in remote locations were tested and developed. The main emphasis was placed on passive samplers for ozone and nitrogenous pollutants (nitrogen oxides, ammonia and nitric acid vapor). In addition, a system for evaluation of total inputs...

متن کامل

Use of bioindicators and passive sampling devices to evaluate ambient ozone concentrations in north central Pennsylvania.

Ambient concentrations of tropospheric ozone and ozone-induced injury to black cherry (Prunus serotina) and common milkweed (Asclepias syriaca) were determined in north central Pennsylvania from 29 May to 5 September 2000 and from 28 May to 18 September 2001. Ogawa passive ozone samplers were utilized within openings at 15 forested sites of which six were co-located with TECO model 49 continuou...

متن کامل

Estimates of ozone AOT40 from passive sampling in forest sites in South-Western Europe.

Weekly-fortnightly ozone (O3) concentrations measured by passive sampling at 81 forest monitoring plots in France, Italy, Spain and Switzerland over the period 2000-2002 were used to estimate the cumulative exposure index AOT40. The estimation method is based on a deterministic model which describes the O3 daily profile as a function of relative altitude (the difference between the altitude of ...

متن کامل

Determination of nitrogen dioxide, sulfur dioxide, ozone, and ammonia in ambient air using the passive sampling method associated with ion chromatographic and potentiometric analyses

Concentrations of nitrogen dioxide (NO(2)), sulfur dioxide (SO(2)), ozone (O(3)), and ammonia (NH(3)) were determined in the ambient air of Al-Ain city over a year using the passive sampling method associated with ion chromatographic and potentiometric detections. IVL samplers were used for collecting nitrogen and sulfur dioxides whereas Ogawa samplers were used for collecting ozone and ammonia...

متن کامل

Quantifying the spatial and temporal variation of ground-level ozone in the rural Annapolis Valley, Nova Scotia, Canada using nitrite-impregnated passive samplers.

The spatiotemporal variability of ground-level ozone (GLO) in the rural Annapolis Valley, Nova Scotia was investigated between August 29, 2006, and September 28, 2007, using Ogawa nitrite-impregnated passive diffusion samplers (PS). A total of 353 PS measurements were made at 17 ambient and 1 indoor locations over 18 sampling periods ranging from 2 to 4 weeks. The calculated PS detection limit ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Air & Waste Management Association

دوره 54 10  شماره 

صفحات  -

تاریخ انتشار 2004