Field Testing of Cavity Ring-Down Spectroscopy Analyzers Measuring Carbon Dioxide and Water Vapor

نویسندگان

  • SCOTT J. RICHARDSON
  • NATASHA L. MILES
  • KENNETH J. DAVIS
  • ERIC R. CROSSON
  • CHRIS W. RELLA
  • ARLYN E. ANDREWS
چکیده

Prevalent methods for making high-accuracy tower-based measurements of the CO2 mixing ratio, notably nondispersive infrared spectroscopy (NDIR), require frequent system calibration and sample drying. Wavelength-scanned cavity ring-down spectroscopy (WS-CRDS) is an emerging laser-based technique with the advantages of improved stability and concurrent water vapor measurements. Results are presented from 30 months of field measurements from WS-CRDS systems at five sites in the upper Midwest of the United States. These systems were deployed in support of the North American Carbon Program’s Mid-Continent Intensive (MCI) from May 2007 to November 2009. Excluding one site, 2s of quasi-daily magnitudes of the drifts, before applying field calibrations, are less than 0.38 ppm over the entire 30-month field deployment. After applying field calibrations using known tanks sampled every 20 h, residuals from known values are, depending on site, from 0.02 60.14 to 0.17 60.07 ppm. Eight months of WS-CRDS measurements collocated with a National Oceanographic and Atmospheric Administrations (NOAA)/Earth System Research Laboratory (ESRL) NDIR system at West Branch, Iowa, show median daytime-only differences of 20.13 60.63 ppm on a daily time scale.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and performance of a Nafion dryer for continuous operation at CO2 and CH4 air monitoring sites

In preparation for routine deployment in a network of greenhouse gas monitoring stations, we have designed and tested a simple method for drying ambient air to near or below 0.2 % (2000 ppm) mole fraction H2O using a Nafion dryer. The inlet system was designed for use with cavity ring-down spectrometer (CRDS) analyzers such as the Picarro model G2301 that measure H2O in addition to their princi...

متن کامل

Evanescent Wave Cavity Ring-down Spectroscopy: a Future Technology for Process Sensing

Evanescent wave cavity ring-down spectroscopy (EW-CRDS) is described. The total internal reflection (TIR)-ring and monolithic folded cavity designs are briefly discussed. The performance of EW-CRDS for trace water vapor detection is evaluated by accounting for surface chemical and physical properties as well as intrinsic resonator properties. INTRODUCTION Cavity ring-down spectroscopy (CRDS) us...

متن کامل

Demonstration of high-precision continuous measurements of water vapor isotopologues in laboratory and remote field deployments using wavelength-scanned cavity ring-down spectroscopy (WS-CRDS) technology.

This study demonstrates the application of Wavelength-Scanned Cavity Ring-Down Spectroscopy (WS-CRDS) technology which is used to measure the stable isotopic composition of water. This isotopic water analyzer incorporates an evaporator system that allows liquid water as well as water vapor to be measured with high precision. The analyzer can measure H2(18)O, H2(16)O and HD(16)O content of the w...

متن کامل

No influence of CO2 on stable isotope analyses of soil waters with off‐axis integrated cavity output spectroscopy (OA‐ICOS)

RATIONALE It was recently shown that the presence of CO2 affects the stable isotope (δ2 H and δ18 O values) analysis of water vapor via Wavelength-Scanned Cavity Ring-Down Spectroscopy. Here, we test how much CO2 is emitted from soil samples and if the CO2 in the headspace influences the isotope analysis with the direct equilibration method by Off-Axis Integrated Cavity Output Spectroscopy (OA-...

متن کامل

Cavity-Ring-Down Spectroscopy on Water Vapor in the Range 555-604 nm.

The method of pulsed cavity-ring-down spectroscopy was employed to record the water vapor absorption spectrum in the wavelength range 555-604 nm. The spectrum consists of 1830 lines, calibrated against the iodine standard with an accuracy of 0.01 cm(-1); 800 of these lines are not obtained in the HITRAN 96 database, while 243 are not included in the newly recorded Fourier transform spectrum of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012