Quantitative evaluation of anterior segment parameters in the era of imaging.

نویسندگان

  • Syril Dorairaj
  • Jeffrey M Liebmann
  • Robert Ritch
چکیده

PURPOSE To review the parameters for quantitative assessment of the anterior segment and iridocorneal angle and to develop a comprehensive schematic for the evaluation of angle anatomy and pathophysiology by high-resolution imaging. METHODS The published literature of the last 15 years was reviewed, analyzed, and organized into a construct for assessment of anterior segment processes. RESULTS Modern anterior segment imaging techniques have allowed us to devise new quantitative parameters to improve the information obtained. Ultrasound biomicroscopy, slit-lamp optical coherence tomography, and anterior segment optical coherence tomography provide high-resolution images for analysis of physiologic and pathologic processes. These include iridocorneal angle analysis (eg, angle opening distance, angle recess area, trabecular-iris space area), anterior and posterior chamber depth and area, iris and ciliary body cross-sectional area and volume, quantitative anatomic relationships between structures, and videographic analysis of iris movement and accommodative changes under various conditions. Modern devices permit imaging of the entire anterior chamber, allowing calculation of anterior chamber and pupillary diameters and correlating these with measurement of anterior chamber dynamics in light vs dark conditions. We have tabulated all reported anterior segment measurement modalities and devised a construct for assessment of normal and abnormal conditions. CONCLUSION Quantitative measurement of static and dynamic anterior segment parameters, both normal and abnormal, provides a broad range of parameters for analysis of the numerous aspects of the pathophysiology of the anterior segment of the eye.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the potential impact of reconstruction method on dyssynchrony parameters derived by phase analysis of gated-SPECT MPI: Comparison of two quantitative software

Introduction: Gated SPECT myocardial perfusion scanning has new capabilities in addition to its main applications such as left ventricular dyssynchrony using phase analysis. Phase analysis has been investigated through various software including Emory Cardiac Toolbox (ECTb) and Quantitative Gated SPECT (QGS). The aim of this study is to evaluate the effect of reconstruction par...

متن کامل

Anterior Segment Time Domain Optical Coherence Tomography

To compare anterior segment parameters using quantitative imaging by anterior segment time domain optical coherence tomography (AS-OCT) and high frequency ultrasound biomicroscopy (HF-UBM). SETTING: Department of Ophthalmology at Bari University. METHODS: Seventy-two eyes of 72 subjects had anterior segment evaluation by AS-OCT (Stratus ver 6Zeiss) and HF-UBM (OTI-Scan HF35-50). Central corneal...

متن کامل

Estimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study

Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...

متن کامل

Refractive Error and Anterior Segment Parametric Changes in Patients with Posterior Capsular Opacification after Nd: YAG Laser Posterior Capsulotomy

Background and Objective: Cataract is one of the most common causes of blindness in the world, and posterior capsular opacification (PCO) is the most common complication after cataract surgery. Nd: YAG laser posterior capsulotomy is a standard method for the treatment of PCO. The aim of this study was to investigate the effects of Yas laser capsulotomy on anterior segment parameters and lenticu...

متن کامل

Evaluating the Effect of Injected Dose of 99mTc- MIBI on the Quantitative Parameters of Myocardial Perfusion Imaging

Background: 99mTc-MIBI cardiac perfusion scanning is recognized as a clinically useful method in evaluating coronary artery disease. By the implementation of new imaging techniques and systems, it seems possible to obtain high-quality images with a lower dose of radiopharmaceuticals. The purpose of this study was to evaluate the effect of injection dose of 99mTc-MIBI on quantitative parameters ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Transactions of the American Ophthalmological Society

دوره 105  شماره 

صفحات  -

تاریخ انتشار 2007