PURPOSE To determine the sensitivity and specificity of anterior and posterior corneal elevation parameters as determined by Orbscan II (Bausch and Lomb, Rochester, NY, USA) in discriminating between (sub) clinical keratoconus (KCN) and normal corneas. METHODS This prospective case-control study included 28 eyes with subclinical KCN, 65 with clinical KCN and 141 normal corneas. Anterior and posterior corneal elevation was measured and compared in the central 5-mm corneal zone using Orbscan II. RESULTS Receiver operating curves (ROC) curve analyses for posterior corneal elevation showed predictive accuracy in both KCN and subclinical KCN with an area under the curve (AUC) of 0.97 and 0.69, respectively while optimal cutoff points were 51 μm for KCN and 35 μm for subclinical KCN. These values were associated with sensitivity and specificity of 89.23% and 98.58%, respectively, for KCN; and 50.00% and 88.65% for subclinical KCN. ROC curve analyses for anterior corneal elevation showed predictive accuracy in both KCN and subclinical KCN with AUC of 0.97 and 0.69, respectively while optimal cutoff points were 19 μm for KCN and 16 μm for subclinical KCN. These values were associated with sensitivity and specificity of 93.85% and 97.16%, respectively, for KCN; and 60.71% and 87.94% for subclinical KCN. CONCLUSION Anterior and posterior corneal elevation data obtained by Orbscan II can well discriminate between KCN and normal corneas, however the reliability of their indices is lower in differentiating subclinical KCN from normal cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تغییرات برآمدگی سطح خلفی قرنیه پس از جراحی فتورفرکتیوکراتکتومی

  Background : Posterior corneal elevation changes are keys to early diagnosis of corneal ectasia after keratorefractive surgery, so it is important to use an accurate method for measuring posterior corneal elevation. The purpose of this study is investigating posterior corneal elevation changes with Pentacam(HR) on patients underwent photorefractive keratectomy.   Methods: In this clinical tri...

متن کامل

Efficacy of Orbscan II and Pentacam topographers by a repeatability analysis when assessing elevation maps in candidates to refractive surgery.

INTRODUCTION Anterior and posterior corneal elevations are measurements used to detect keratoconus suspects. PURPOSE To determine the efficacy of Orbscan II and Pentacam when assessing their elevation maps. MATERIALS AND METHODS The efficacy of the Orbscan II and Pentacam measuring the anterior and posterior corneal elevations were evaluated in a sample of 68 eyes. The concordance between t...

متن کامل

Early diagnosis of keratoconus: what difference is it making?

WHY EARLY DIAGNOSIS? In corneal refractive surgery, early diagnosis of keratoconus (subclinical asymptomatic keratoconus) is of great importance in patients seeking surgery because it can prevent progression of the pathology after surgery and make it symptomatic (corneal ectasia), thus creating the need for diagnostic tests that provide high sensitivity (ability to detect the disease in affecte...

متن کامل

Early diagnosis of keratoconus: what difference is it making?

WHY EARLY DIAGNOSIS? In corneal refractive surgery, early diagnosis of keratoconus (subclinical asymptomatic keratoconus) is of great importance in patients seeking surgery because it can prevent progression of the pathology after surgery and make it symptomatic (corneal ectasia), thus creating the need for diagnostic tests that provide high sensitivity (ability to detect the disease in affecte...

متن کامل

The Challenges of the Detection of Subclinical Keratoconus at Its Earliest Stage

Undetected subclinical keratoconus (KC) is the main risk factor for iatrogenic ectasia. Many parameters have been proposed to help differentiate normal from subclinical KC corneas. Linear discriminant analysis is a technique that models the difference between different classes of data by looking for linear combinations of variables which best explain the data. The association of surfaces elevat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015